Manual Do Utilizadoríndice analíticoSECTION 1: Concept1SECTION 2: The CRV-Series System22.1 Safety22.2 Zero Regulator22.3 Fuel Savings and Comfort4SECTION 3: Clearances to Combustibles53.1 Required Clearances to Combustibles5SECTION 4: Sizing and Design Considerations94.1 Radiant Adjustment to Heat Loss94.2 Radiant Height Adjustment Factor94.3 Selecting the Burners104.4 Radiant Distribution10SECTION 5: Flow Loading125.1 Radiant Branch Flow125.2 Pump Capacity145.3 Tailpipe Flow14SECTION 6: Radiant Tube and Tailpipe156.1 Radiant Tube Length156.2 Tailpipe156.3 Design Parameters166.4 CRV-Series Design Methods166.5 Tailpipe Design Method18SECTION 7: Example CRV-Series System Layouts217.1 Example System Layout (Option 1)217.2 Example System Layout (Option 2)227.3 Example System Layout (Option 3)227.4 Example System Layout (Option 4)237.5 Example System Layout (Option 5)237.6 Example System Layout (Option 6)247.7 Example System Layout (Option 7, 8 and 9)25SECTION 8: Control Methods26(P/N 02770002)268.2 ROBERTS GORDON® ULTRAVAC™268.3 SPST Transformer Relay (P/N 90417600K)278.4 DPST Transformer Relay (P/N 90436300)278.5 Pressure Switch27SECTION 9: Air Supply System289.1 Pressurized289.2 Non-Pressurized289.3 Outside Air System Design Requirements28Requirements31SECTION 11: CRV-Series Equipment Specifications3211.1 Burner and Burner Controls3211.2 Equipment32Figure 1: Assembly Overview (Two Branch System Shown)3Figure 2: Standard Reflector6Figure 3: One Side Reflector6Figure 4: Two Side Reflectors6Figure 5: Universal Shield, Position 17Figure 6: Universal Shield, Position 27Figure 7: Universal Shield, Position 37Figure 8: 2-Foot Deco Grille8Figure 9: Barrier Shield8Figure 10: Protective Grille8Figure 11: Radiant Distribution (Average Coverage)11Figure 12: Radiant Distribution (Increased Coverage)11Figure 13: Radiant Distribution (Heavy Coverage)11Figure 14: Burner Flow Units13Figure 15: Vacuum Loss Curve for 4" Shared Tailpipe14Figure 16: Tube Length vs. Efficiency16Figure 17: Possible Damper Coupling Locations20Figure 18: Example System Layout (Option 1)21Figure 19: Example System Layout (Option 2)22Figure 20: Example System Layout (Option 3)22Figure 21: Example System Layout (Option 4)23Figure 22: Example System Layout (Option 5)23Figure 23: Example System Layout (Option 6)24Figure 24: Example System Layout (Option 7)24Figure 25: Example System Layout (Option 8)24Figure 26: Example System Layout (Option 9)25Diameter28Figure 28: Outside Air Blower29Systems30Table 1: CORAYVAC® Design Parameters12Table 2: Pump Capacity14Table 3: Pump Exhaust Requirements14Table 4: Allowable Tailpipe Lengths17Non-Condensing18Tamanho: 2 MBPáginas: 40Language: EnglishAbrir o manual