OPERATING HEATER
Continued
Note:
 The correct pilot flame on natural gas units 
will have a slight curve, but flame should be blue 
and have no yellow or orange color.
Figure 18 - Correct Pilot Flame Pattern 
(Propane/LP Shown)
Thermocouple
Pilot 
Burner
Pilot Burner
Thermocouple
Figure 19 - Incorrect Pilot Flame Pattern 
(Propane/LP Shown)
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise 
 to the 
OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise 
 to the 
PILOT position.
THERMOSTAT CONTROL 
OPERATION
The thermostat control knob can be set to any 
comfort level between HI and LO. The ther-
mostat will gradually modulate the heat output 
and flame height from higher to lower settings 
or pilot, in order to maintain the comfort level 
you select. The ideal comfort setting will vary 
by household depending upon the amount of 
space to be heated, the output of the central 
heating system, etc.
Note:
 Selecting the HI setting with the control 
knob will cause the burner to remain fully on, 
without modulating down in most cases.
MANUAL LIGHTING 
PROCEDURE
1.  Follow steps 1 through 5 under Lighting 
Instructions
, page 13.
2.  Depress control knob and light pilot with 
match. 
3.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob. Now follow step 8 in Lighting 
Instructions
, page 13. 
INSPECTING BURNERS
Check pilot flame pattern and burner flame pat-
terns often.
PILOT FLAME PATTERN
Figure  18  shows  a  correct  pilot  flame  pattern. 
Figure 19 shows an incorrect pilot flame pattern. 
The  incorrect  pilot  flame  is  not  touching  the 
thermocouple. This will cause the thermocouple 
to cool. When the thermocouple cools, the heater 
will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 19
•  turn  heater  off  (see  To  Turn  Off  Gas  to 
Appliance
)
•  see Troubleshooting, page 16
CLEANING AND 
MAINTENANCE
  WARNING:  Turn  off  heater 
and let cool before cleaning.
 CAUTION: You must keep con-
trol areas, burner and circulating 
air passageways of heater clean. 
Inspect  these  areas  of  heater 
before  each  use.  Have  heater 
inspected  yearly  by  a  qualified 
service person. Heater may need 
more  frequent  cleaning  due  to 
excessive lint from carpeting, pet 
hair, bedding material, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clear may result in 
sooting and property damage.
MAIN BURNER
Periodically inspect all burner flame holes with 
the heater running. All slotted burner flame holes 
should be open with yellow flame present. All 
round burner flame holes should be open with a 
small blue flame present. Some burner flame holes 
may become blocked by debris or rust, with no 
flame present. If so, turn off heater and let cool. 
Remove blockage. Blocked burner flame holes 
will create soot.