Service Manual – Treadmills: E-Series 
x P-Series
 
61
DFR Code 200 
 
Start
Turn the unit power off at the 
switch.
Measure AC voltage at the wall 
outlet.
Was the AC voltage 
within the specs 
listed above? 
The AC voltage should 
be between:
95 to 125vac for a 110v unit
185 to 250vac for a 220v unit  
G1
No
Check AC voltage coming out of 
the EMI filter
Was the AC voltage within
 the specs listed above? 
G2
No
Yes
Engage Maintenance Mode
(0, 2, start simultaneously)
Yes
Engage Motor Test Mode
(Press ‘8’ after engaging 
Maintenance Mode)
Increase the speed to 5 MPH or 
greater.
Measure AC input voltage with a 
load 
Was the voltage
greater than a 5 volt 
deferential?
The input AC voltage should be 
less than a 5 volt deferential from 
the original AC voltage that was 
taken with out a load
G1
G3
No
Yes
End
DFR Code = 200
DC Link Bus Under Voltage / 10 Blinks
Possible Causes:
(1) Low AC voltage from wall.
(2) Low AC voltage from EMI filter.
(3) Faulty MCB.
Solution:
__          G1_______    
Consult with electrician 
to fix AC input rail 
voltage.
Note: The AC rail 
voltage with a load 
should never drop 
greater than a 5 volt 
deferential comparing it 
with no load. There are 
many equations to 
measure for low rail 
voltage.
Example: If you take a 
person that weighs 200 
Lbs at the speed of 5 
MPH and the voltage 
drops greater than a 5 
volt deferential, the wall 
voltage is not adequate 
and can cause 
intermittent 200 DFR 
codes.
__          G2_______
Replace EMI Filter
__          G3_______
Replace MCB
DFR CODE FLOWCHART: DEFINITIONS / MCB LED Blinks
DFR Flowchart For #: 200