Справочник Пользователя для Toshiba LF654

Скачать
Страница из 14
TIC-LF654L 
Fluid conductivity: 
 3µS/cm minimum  
Fluid temperature:  
-4 to 248 °F (-20 to +120 °C):  
PFA lined flowmeter 
-4 to 140 °F (-20 to +60 °C):  
        Polyurethane lined flowmeter  
23 to 176 °F (- 5to +80 °C):  
    Hard Rubber lined flowmeter 
Ambient temperature: 
-40 to 140 °F (-40 to +60 °C):
 
PFA lined flowmeter  
 -4 to 140 °F (-20 to +60 °C): 
PU lined and HR lined flowmeters 
Structure:   
Standard — IP 67 and NEMA 4X Watertight 
Option — IP68 and NEMA 6P Submersible type 
allows for accidental submergence up to 15m for 
48 hours.  This option is only available when
 
PU 
or HR liners are selected. 
Power consumption:   
Standard:10W(14VA) 
              at  AC100V and Excitation current:0.2A 
MAX:15W (22VA)  
MAX:17W(24VA)  with PROFIBUS  
Approved hazardous location certifications: 
Model: LF654/LF620F and LF654/LF622F 
cFMus Nonincendive for use in  
hazardous (classified) locations: 
Class I, II, III, Division 2, Groups A-G 
Detector and converter combination: 
LF650/LF620: Combined type for standard 
specification. 
LF650/LF622: Separate type for standard 
specification. 
LF654/LF620F: Combined type with Ex approval of 
Class I, II, III,  Division 2 (cFMus). 
LF654/LF622F: Separate type with Ex approval of 
Class I,  II, III, Division 2 (cFMus). 
Mount-Anywhere Technology:   
With TOSHIBA’s unique magnetic field 
distribution technology the meter is highly immune 
to upstream flow disturbances.  
A minimum of 1D (one diameter) length of 
upstream straight pipe from the flange is required to 
maintain the specification performance. 
Note:  The test results were obtained and demonstrated at 
TOSHIBA's flow calibration facility, Fuchu Japan.
 
 
Drinking water approvals: 
PU and HR liner:  NSF certified 
 
 
Model LF654 Detector 
Mounting style: Flange connection type 
Fluid pressure:    
-15 psi or -1.0 bar  (-0.1 MPa) to the nominal 
pressure of the connection flange. 
Note: Before shipping from the manufacturer, each detector 
unit is tested by the following test condition. 
Pressure… twice of the pressure index number  
(ex. 300 psi in case of ASME B 16.5 class 150 flange)  
Time… 15 minutes 
Connection flange standards:  
ASME B16.5 class 150, ASME B16.5 class 300 
EN1092-1 PN10, EN1092-1 PN16 
JIS B 2220 10K, JIS B 2220 20K 
Principal materials: 
Case — carbon steel 
Flange material — carbon steel  
Linings —  
1/2” to 18” (15 to 450mm): PFA  
1/2” to 18” (15 to 450mm): PU 
4” to 18” (100 to 450mm): HR 
Note: PFA liners are mechanically retained for full vacuum 
service (65 to 450 mm). 
Electrodes —  
Type-Super smooth, polished with self cleaning 
finish, and non stick shape 
316L stainless steel (std.) in case of PU and HR 
lining 
Hastelloy C equivalent (std.)  
… in case of PFA lining 
Note: Electrodes are mechanically buffed and 
electro-chemically polished. 
Grounding rings — 316 stainless steel (std.) 
Note:  See Table 4 for optional materials and other 
related information. 
Measuring tube material — 304 stainless steel  
Terminal box material 
—  ADC12(Aluminum 
alloy die casting) 
Coating: Polyurethane resin coating (std.) gray colored 
Dimensions and weights: See Figure 3, 4, 5 and 6. 
Cable connection port: for separate type detectors. 
Cable gland  
LF650: Provided as standard, G 1/2 male screws. 
LF654(with cFMus):Not provided, 3/4–14NPT 
male screws are required. 
Applicable diameter —  
0.433 to 0.512 inch (11 to 13mm)