Справочник Пользователя для Oregon Scientific SE833

Скачать
Страница из 29
E
N
12
CALIBRATE BY INPUTTING PARAMETER
You  can  only  know  your  parameter  if  you  have  already 
successfully  calibrated  by  running  or  walking  beforehand. 
This is because the parameter is the same value displayed 
after you have successfully calibrated by running or walking. 
By  inputting  parameter,  you  will  be  spared  the  time  of 
calibrating by running or walking again.
1.  Press MODE repeatedly to select 
.
2.  Press SET.
3.  Press ST/LAP/+ repeatedly to select “CAL DEVICE”.
4.  Press SET.
5.  Press ST/LAP/+ to select “PARA INPUT”.
6.  Press SET to confirm selection.
7.  Input  parameter  for  Walk  by  pressing  ST/LAP/+  to 
increase  values  or  -  /  SP  to  decrease  values.  The 
parameter is the same value after you have successfully 
calibrated by walking.
8.  Press SET to confirm.
9.  Input  parameter  for  Run  by  pressing  ST/LAP/+  to 
increase  values  or  -  /  SP  to  decrease  values.  The 
parameter is the same value after you have successfully 
calibrated by running.
10. Press SET to confirm.
CONDUCTING EXERCISE
IMPORTANT
  To  ensure  accurate  calculations  with  your 
exercise, you should pair the watch with SZ909 chest belt or 
other devices such as bike pod. However, if without pairing, 
the chest belt will only receive heart rate signal.
There are 2 options for exercise: AUTO and PROG. 
• 
AUTO refers to conducting exercise without using the 
set exercise profile.
• 
PROG refers to conducting exercise by using the set 
exercise profile (refer to “SET EXERCISE PROFILE” 
section in this manual). 
To conduct exercise:
1.  Press MODE to select  
.
•  To exercise without exercise profile, select
available lap
memory
•  To exercise with exercise profile, press ST/LAP/+ to 
select 
available lap
memory
Press  SET,  then  press  -/SP  or  ST/LAP/+  to  select 
which exercise profile to use. 
SE833 EN 11.indd   12
6/1/09   10:07:25 AM