INTRODUCTION
Thank  you  for  selecting  this  Oregon  Scientific
TM
  Heart  Rate 
Logger for your sports and exercise needs. This product allows 
you to record your heart rate information from your chest belt and 
download it to your PC. 
Please keep this manual handy as you use your new product. It 
contains practical step-by-step instructions, as well as technical 
specifications and warnings you should know.
IMPORTANT  The measurement functions built into the WM100 
are  not  meant  to  substitute  professional  measurement  or 
industrial precision devices. Values produced by this unit should 
be considered as reasonable representations only.
OVERVIEW
FRONT VIEW
 
1.   LED indicator
2.   BUTTON 
BACK VIEW
 
1.   Battery compartment
2.   Reset hole
3.   Belt clip
4.   USB cable connection socket
GETTING STARTED
BATTERY
The unit is supplied with a CR2032 cell battery.
The LED indicator will flash red for two seconds before the unit 
turns off to indicate the battery is low.
To change the battery:
1.   Slide the belt clip off the unit.
2.   Use  a  screwdriver  to  remove  the  battery  compartment 
cover.
3.   Replace the battery, matching the polarity (+ / -) as shown.
4.   Reattach the battery compartment cover.
RECORDING YOUR EXERCISE SESSION
 
1.   Set up your chest belt.
2.   Press  BUTTON  to  power  on  the  unit,  and  place  it  next  to 
your chest belt to enable data reception. 
3.   Attach the unit to your belt or place it in your pocket. Start 
exercising.
4.   To  end  data  logging  press  and  hold  BUTTON  for  two 
seconds, until the LED flashes amber, then release.
NOTE   •  The unit has a range of 10cm (4 in) during signal search 
 
   and 80 cm (31.5 in) once a signal has been received.
 
•  Before using for the first time
,
 please install the software 
 
   and connect to your PC to upload time and date  
 
  information.
 
 
CONNECTING TO CHEST BELT
This product is compatible with heart rate chest belts transmitting 
digital  or  analogue  signals  on  5.3kHz  (such  as  the  chest  belts 
supplied  with  the  following  models:  SE102  /  SE200  /  SE211  / 
SE212  /  SE232  /  SE233).  Please  check  your  chest  belt  user 
manual for more information or visit www2.oregonscientific.com
The  unit  will  automatically  search  for  a  signal  whenever  you 
power  ON  the  unit.  The  LED  indicator  will  signal  connection 
status.
LED SIGNAL 
MEANING
GREEN flashes quickly  
Searching for signal
GREEN for 3 seconds 
Signal found
AMBER for 3 seconds 
No signal found
GREEN flashes slowly  
Device activated
NOTE    If no signal is found after 10 seconds the unit will power 
OFF.
SIGNAL RECEPTION
If you change or reset your chest belt during an exercise session, 
it may be necessary to search for the signal again.
To force a signal search:
Press and hold BUTTON for 4 seconds and release when unit 
is ON.  
WARNING    Signal  interference  in  the  environment  due  to 
electromagnetic disturbances may cause unstable or inaccurate 
heart rate readings. These may occur near high voltage power 
lines, traffic lights, overhead lines of electric railways, electric bus 
lines  or  trams,  televisions,  car  motors,  bike  computers,  some 
motor driven exercise equipment, cellular phones or when you 
walk through electric security gates.
LOGGING DATA
Every time the unit receives a signal it starts a new activity record 
and begins to store heart rate data. The LED indicator will flash 
green every 3 seconds to indicate data is being received.
As  soon  as  the  unit  stops  receiving  data  or  is  turned  off  the 
activity record is ended.
To end an activity record / turn unit OFF:
1.   Press and hold BUTTON for 2 seconds. The LED will turn 
amber.
2.   Release BUTTON to turn OFF.
NOTE  The unit will automatically deactivate if no heart rate is 
detected for 5 minutes, during this time the LED will continue to 
flash green. The unit will also deactivate if the battery is low or if 
the memory is full.
MEMORY 
The data logger can record up to 30 hours at a storage interval of 
2 seconds.  Up to 99 activity records can be stored. 
LED SIGNAL 
MEANING
RED flashes slowly   
90% of memory full
during exercise 
RED steady for 2  
Memory full, the unit will  
seconds 
automatically turn OFF
Memory  records  can  be  deleted  manually  or  by  using  the 
SmartSync  PC  software  supplied  with  this  product.  To  delete 
using your PC, please refer to the software Help file. 
To manually delete all activity records:
1.   Press and hold BUTTON for 4 seconds (when unit is OFF). 
The LED will flash amber.
2.   Press again to clear memory. 
3.   The LED will turn green for 1 second to indicate records are 
deleted
.
TIP    To maximise the product lifetime we recommend waiting until 
the memory is nearly full before uploading the data to your PC. 
CONNECTING TO YOUR PC 
To  connect  to  your  PC  insert  the  USB  cable  into  your  PC  and 
attach to the Heart Rate Logger.
 
RESET
To reset use a thin blunt object to press RESET.
PRECAUTIONS
This  product  is  engineered  to  give  you  years  of  satisfactory 
service if you handle it carefully. Here are a few precautions:
•   Do  not  subject  the  unit  to  excessive  force,  shock,  dust, 
temperature  or  humidity,  which  may  result  in  malfunction, 
shorter electronic life span, damaged battery and distorted 
parts.
•   Do not immerse the unit in water. If you spill liquid over it, dry 
it immediately with a soft, lint-free cloth.
•   Do not clean the unit with abrasive or corrosive materials. 
•   Do  not  tamper  with  the  unit’s  internal  components.  Doing 
so  will  invalidate  the  warranty  on  the  unit  and  may  cause 
unnecessary damage. The unit contains no user-serviceable 
parts.
•   Only use fresh batteries as specified in the user’s instructions. 
Do not mix new and old batteries.
•   Due to printing limitations, the displays shown in this manual 
may differ from the actual display.
•   The contents of this manual may not be reproduced without 
the permission of the manufacturer.
•   Do  not  dispose  this  product  as  unsorted  municipal  waste. 
Collection of such waste separately for special treatment is 
necessary.
NOTE    The  technical  specifications  for  this  product  and  the 
contents  of  the  user  manual  are  subject  to  change  without 
notice.
SPECIFICATIONS
TYPE 
DESCRIPTION
L x W x H 
46 x 46 x 17 mm 
 
(1.8 x 1.8 x 0.7 in)
Reception range  
10 cm (4 in) signal search
 
80 cm (31.5 in) signal found
Signal reception  
5.3 kHz digital / analogue
Memory 
30 hrs (at 2 sec intervals)
 
99 activity records
Power  
1 x CR2032 cell battery.
ABOUT OREGON SCIENTIFIC
Visit  our  website  (www.oregonscientific.com)  to  learn  more 
about Oregon Scientific products such as digital cameras; MP3 
players;  children’s  electronic  learning  products  and  games; 
projection  clocks;  health  and  fitness  gear;  weather  stations; 
and  digital  and  conference  phones.  The  website  also  includes 
contact information for our Customer Care department in case 
you need to reach us, as well as frequently asked questions and 
customer downloads.
We hope you will find all the information you need on our website, 
however if you’re in the US and would like to contact the Oregon 
Scientific Customer Care department directly, please visit: 
http://www2.oregonscientific.com/service/default.asp
OR 
Call 1-800-853-8883. 
For international inquiries, please visit: 
www2.oregonscientific.com/about/international.asp
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Universal Wireless 
Heart  Rate  Data  Logger  (WM100)  is  in  compliance  with  EMC 
directive 89/336/CE. A copy of the signed and dated Declaration 
of Conformity is available on request via our Oregon Scientific 
Customer Service.
 
  Universal  Wireless  Heart  Rate  Data 
Logger with PC Download
 Model: WM100
USER MANUAL
2
1
1
2
3
4
1
3
2
4
EN
 © 2006 Oregon Scientific. All rights reserved.    
086L004464-037
          
                  
WM100_M_USA_OP.indd   1
5/4/06   12:18:51 PM