Справочник Пользователя для Mitsubishi Electronics QJ71LP21GE

Скачать
Страница из 400
 
 
 
7 - 13                                                                                                                                                                                                          7 - 13 
MELSEC-Q
7   APPLICATION FUNCTIONS 
 
7.5 Return Sequence Station Number Setting Function 
Master Remote 
 
 
 
The remote I/O net can set the number of stations for which stations with 
communication errors during one link scan can perform return sequence.      If the 
number of stations set is large, a large number of communication stations with errors 
can perform return sequence. However, link scan during return sequence will take 
longer than a normal link scan so care must be taken to lengthen the link scan to 
match if the setting for return sequence is increased. 
(Normally there is no problem using the default settings.) 
The maximum number of return sequence stations is set in the supplementary settings 
for the common parameters. 
The setting range is 1 to 64 stations. 
The default is set to 2 stations. 
 
7.6 Reserved Station Function 
Master Remote 
 
 
 
The reserved station designation is a function that handles stations to be connected in 
the future as stations with communication errors. (These stations are not actually 
connected, but they are included in the total number of stations (remote) in the 
network.) 
Since reserved stations do not affect scan time, full performance can be realized even 
when they remain reserved. 
Reserved stations are set in the common parameters.