3   SPECIFICATIONS 
 
3.1.2 Coaxial cable system performance specifications 
Table 3.2 lists the performance of the coaxial bus system. 
 
Table 3.2    Coaxial cable system performance specifications 
Item 
Remote master station 
Remote I/O station 
QJ71BR11 QJ72BR15 
Maximum 
number of links 
per network 
LX/LY 8192 
points 
LB 
16384 points (Remote master station 
  remote sub-master station, remote I/O station: 8192 points, remote sub-master 
station, remote I/O station 
  remote master station: 8192 points) 
LW 
16384 points (Remote master station 
  remote sub-master station, remote I/O station: 8192 points, remote sub-master 
station, remote I/O station 
  remote master station: 8192 points) 
Maximum number of links per 
station 
•  Remote Master Station 
  Remote I/O station ((LY + LB)/8 + (2 
 LW)) 
 1600 bytes
1
 
•  Remote I/O station 
  Remote Master Station    ((LX + LB)/8 + (2 
 LW)) 
 1600 bytes 
•  Multiplexed remote master station 
  multiplexed remote sub-master station ((LY + LB) /8 + (2 
 LW)) 
 2000 bytes
Maximum I/O points per remote I/O 
station 
X + Y 
 4096 points 
If the X/Y numbers are the same, only one side is taken into consideration. 
Device points per 
remote I/O 
station 
M  
8192 
points 
SM  
2048 
points 
D 12288 
points 
SD  
2048 
points 
Communication speed 
10 Mbps 
Number of stations per network 
33 stations (Remote master stations: 1          Remote I/O stations: 32)
2
 
Overall distance 
3C-2V 
300 m (Between stations 300 m) 
3
 
5C-2V 
500m (Between stations 500 m) 
3
 
5C-FB 
500m (Between stations 500 m) 
3
 
 
Can be extended up to 2.5 km with the use of a repeater (A6BR10,A6BR10-DC) 
Maximum number of networks 
239 (Total including PLC to PLC networks) 
Transmission path format 
Single layer bus 
Communication method 
Token bus 
Synchronization method 
Frame synchronization 
Coding method 
Manchester code 
Transmission format 
HDCL standards (Frame format) 
Error control 
CRC (X
16
 + X
12
 + X
5
 + 1) and retry by timeover 
RAS functions 
•    Station separation function due to error detection or cable disconnection 
•    Diagnostic function for checking local link lines 
•    Detection using link special relays or link special registers 
•    Configuring a redundant power supply on a remote I/O station 
•    Online module change in a remote I/O station 
Application function 
•    Remote password for remote I/O station 
Transient transmission 
•    1:1 communication (Monitor, program upload/download, etc.) 
•    Various send/receive commands from the programmable controller program (READ/WRITE,REMFR/REMTO) 
Maximum number of modules per 
CPU 
4 modules 
— 
Number of I/O points 
32 points (Intelligent function module: 32 points) 
— 
5 V DC internal current consumption 
0.75 A 
1.10 A 
External dimensions 
98 (3.86)(H) 
 27.4 (1.08)(W) 
  90 (3.54)(D) [mm (inch)] 
Weight 
0.11 kg 
0.16 kg 
1:  The remote master station includes the multiplexed remote master station and multiplexed remote sub-master station. 
2:  On a multiplexed remote I/O network, one of 32 remote I/O stations works as a multiplexed remote sub-master station.
 
3:  There are restrictions on the interstation cable length depending on the number of connected stations. Refer to Section 4.8.2 for 