Справочник Пользователя для Mitsubishi Electronics -NZ2GF2B-60DA4
135
CHAPTER 11 TROUBLESHOOTING
11
11.1 C
hecking for t
he Erro
r Codes and t
he Alar
m Codes
CHAPTER 11
TROUBLESHOOTING
This chapter describes errors that may occur while the D/A converter module is used, and those troubleshooting.
11.1
Checking for the Error Codes and the Alarm Codes
Error codes can be checked by any of the following methods:
• Checking by executing a command of the slave station (
• Checking by Latest error code (RWr0) (
• Checking by Latest warning code (RWr1) (
Alarm codes can be checked by any of the following methods:
• Checking by executing a command of the slave station (
• Checking by Latest warning code (RWr1) (
(1) Checking by executing a command of the slave station
This section describes how to check the errors by executing a command of the slave station.
1.
Select the D/A converter module in "List of stations"
on the "CC IE Field Configuration" window.
2.
Open the "Command Execution of Slave Station"
window.
[CC IE Field Configuration]
[Online]
[Command Execution of Slave Station]
3.
Set "Method selection" to "Error history read" and
click the
button.
List of
stations
stations