Справочник Пользователя для Mitsubishi Electronics -NZ2GF2B-60DA4

Скачать
Страница из 198
23
CHAPTER 3 SPECIFICATIONS
3
3.1  Gener
al Specifications
  
CHAPTER 3
SPECIFICATIONS
This chapter describes the specifications of the D/A converter module.
3.1
General Specifications
*1
Do not use or store the D/A converter module under pressure higher than the atmospheric pressure of altitude 0m. 
Doing so may cause malfunction. When using the D/A converter module under pressure, please consult your local 
Mitsubishi representative.
*2
If the environment satisfies the operating ambient temperature, operating ambient humidity and other conditions, the 
module can be used even outside the control panel.
*3
This indicates the section of the power supply to which the equipment is assumed to be connected between the public 
electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand 
level for the equipment with the rated voltage of 300V or less is 2500V.
*4
This index indicates the degree to which conductive material is generated in terms of the environment in which the 
equipment is used.
Pollution degree 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing must 
be expected occasionally.
Item
Specifications
Operating 
ambient 
temperature
0 to 55°C
Storage ambient 
temperature
-25 to 75°C
Operating 
ambient humidity
5 to 95%RH, non-condensing
Storage ambient 
humidity
Vibration 
resistance
Compliant with 
JIS B 3502 and 
IEC 61131-2
Frequency
Constant 
acceleration
Half amplitude
Number of 
sweeps
Under 
intermittent 
vibration
5 to 8.4Hz
-
3.5mm
10 times each in 
X, Y, and Z 
directions
8.4 to 150Hz
9.8m/s
2
-
Under continuous 
vibration
5 to 8.4Hz
-
1.75mm
-
8.4 to 150Hz
4.9m/s
2
-
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 (147m/s
2
, 3 times each in X, Y, and Z directions)
Operating 
atmosphere
No corrosive gases
Operating 
altitude
*1
0 to 2000m
Installation 
location
Inside a control panel
*2
Overvoltage 
category
*3
II or less
Pollution 
degree
*4
2 or less
Equipment class
Class I