3.2.1  Setting the Start Address
Each Pelco CM9760-IRC unit requires a six-bit start address. The start address is
configured using the DIP switches on the communication card (see Figure 5: DIP
switches). Each control card occupies one address space. An IRC unit occupies
four address spaces (if there are only two control cards in the unit, it still occupies
four address spaces).
The start address of an IRC unit is set with the DIP switches on the communication
card per Table B.
Table B.  Start Addresses
DIP
DIP
DIP
DIP
DIP
DIP
Start Address
Start Address
Switch  8
Switch  7
Switch  6
Switch  5
Switch  4
Switch  3
(Binary)
(Decimal)
ON
ON
ON
ON
ON
ON
000000
0
ON
ON
ON
ON
ON
OFF
000001
1
ON
OFF
ON
ON
ON
ON
010000
16
ON
OFF
ON
ON
OFF
ON
010010
18
OFF
OFF
ON
ON
OFF
ON
110010
50
OFF
OFF
OFF
OFF
OFF
ON
111110
62
Unlike an IRC unit, a serial GPI occupies one address space. In the sample system
outlined in Figure 3, the start addresses would set up according to Table C.
Table C.  Start Addresses
Device
Address (Decimal)
Address (Binary)
Serial GPI
 0
 000000
Set via serial GPI communication
card DIP switches
IRC unit 1/control card 1
 1
 000001
Set via IRC unit 1 communication
card DIP switches
Control card 2
2
000010
Automatic internal default
Control card 3
3
000011
Automatic internal default
Control card 4
4
000100
Automatic internal default
NOTE: 
It is necessary only to set the
start address of the IRC as a whole.
The start  address of each control
card in the unit is set by internal de-
fault.