10-5  Regular Checks
  Cha
p
te
r 10  Maint
ena
nc
e and
 In
s
p
e
c
tion
To display the digital hours meter
Select F9 (MENU), then turn the MULTI CONTROL 
knob to display the required item in the time data display.
To exit the digital hours meter
Select F10 (EXIT).
10-5-2   Maintenance Timings
Use the following table as a timing guide for checking and 
replacing components of the unit.
These intervals are not guaranteed lifetimes; the timing for 
replacing components depends on the conditions of use. In 
particular, depending on the degree of contamination and 
abrasion, pinch rollers and cleaners may require 
replacement earlier than suggested by this table.
Note that an arrow in the table means that the component 
to be replaced is part of the assembly the arrow points to, 
which must be replaced as a whole.
For information on severe conditions (frequent threading/
unthreading) or how to replace components, refer to the 
Maintenance Manual Volume 1.
For  replacement and checking of components, contact a 
Sony service or marketing representative. 
MULTI CONTROL knob
F9 (MENU)
F10 (EXIT)
Component
Digital hours meter 
indication (menu item 
number in parenthesis)
Guideline for replacement and checking intervals
R: Replace        C: Check, and replace if necessary
1000 (h)
2000 
3000 
4000 
5000 
6000 
Upper drum
Drum running time (H02)
C
C
C
C(
r)
Drum assembly
C
Brush slip ring assembly
R
R(
R)
Video head cleaner (roller)
R
R
Pinch roller assembly
Tape running time (H03)
R
R
Reel table assembly
R (Replace every 4,000 hours.)
Pinch application assembly  Tape running time (H03)
R
Fan motor (card)
Operation time (H01)
Replace every 40,000 hours
Fan motor (MD)
Replace every 40,000 hours
Fan motor (power supply)
Replace every 40,000 hours
Note