4-1  Recording
  C
h
ap
te
r 4
  
R
e
c
o
rd
in
an
d
 P
la
y
ba
c
k
5
Until all the digits are set as required, repeat steps 3 
and 4.
6
Select F9 (SET).
When F3 (TCG RUN) in function menu page P02: TC 
is set to “FREE”, the timecode value starts advancing 
immediately. 
To set the timecode value to the real time
With the items in function menu page P02: TC set as 
follows, carry out the procedure of “Setting an initial 
timecode value”. In steps 3 and 4, set a value slightly after 
the current time as the initial value, then carry out step 6 at 
the instant the real time catches up with the setting. 
F1 (TCG SRC): INTERNAL
F2 (TCG MODE): PRESET
F3 (TCG RUN): FREE
F4 (DROP FRM): DF (59.94i, 29.97PsF mode only)
To set a user bit value
The user bit values recorded on the timecode track provide 
for eight hexadecimal digits, which can be used to hold the 
date, time, or other information.
Use the following procedure.
In function menu page P02: TC, select and set F1 (TCG 
SRC) to “INTERNAL” and F2 (TCG MODE) to 
“PRESET”, respectively. 
1
In function menu page P01: HOME, set F8 
(COUNTER) to “UB”.
2
Carry out the procedure in steps 2 to 6 under the 
heading above, “Setting an initial timecode value”.
Set values, using the hexadecimal digits 0 to 9 and A 
to F. 
If any of the settings of “REC START MARK MODE” in 
setup menu item 631 is set to “ON” (to write a recording 
start mark), then the user bits are overwritten with the shot 
mark data for 20 frames from the start of recording in crash 
record mode, assemble edit mode, or insert edit mode.
For details on the setup menu, see Chapter 9 “Setup 
Menus”.
To synchronize the internal timecode 
generator with an external signal
Use this method to synchronize the timecode generators of 
multiple VTRs, or to record the playback timecode signal 
from an external VTR without deterioration of the signal 
waveform.
In this case the RUN and DF settings are ignored.
You can synchronize the internal timecode generator with 
either of the following external timecodes.
• The timecode output (LTC) of an external timecode 
generator or external VTR connected to the TIME 
CODE IN connector of the unit
• The timecode (LTC or VITC) in the HDSDI signal input 
to the unit
To synchronize the internal timecode generator with an 
external signal, use the following procedure.
1
Set “TCG REGEN MODE” in setup menu item 605 to 
“TC&UB” or “TC”.
2
To synchronize with an external timecode signal input 
to this unit’s TIME CODE IN connector, connect an 
external timecode generator or external VTR's 
timecode output to the TIME CODE IN connector.
To synchronize with a timecode data contained in an 
HDSDI signal input to this unit, set F1 (VIDEO IN) to 
“SDI” in function menu page P01: HOME.
3
Set the timecode generator items as follows.
To synchronize with an external timecode signal 
input to this unit’s TIME CODE IN connector:
• In function menu page P02: TC, set F1 (TCG SCR) 
to “EXT LTC”.
To synchronize with the LTC data contained in an 
HDSDI signal input to this unit:
• Set F1 (TCG SRC) to “SDI IN”.
• Set F2 (TCG MODE) to “RGN:LTC”.
To synchronize with the VITC data contained in an 
HDSDI signal input to this unit:
• Set F1 (TCG SRC) to “SDI IN”.
• Set F2 (TCG MODE) to “RGN:VITC”.
The unit starts the internal timecode generator running 
in synchronization with the external timecode 
generator.
The internal timecode generator is synchronized, and 
even if the external timecode generator is 
Note
1,2,3
TIME CODE
IN
OUT
1