 Error Messages and Warning Messages
  
App
end
ix
Warning Messages
When one of the problems described below is detected, a 
warning mark is displayed in the upper left corner of the 
display. Operation can continue even when the mark is 
flashing.
If you press the SFT button (see page 19) and the DIAG 
button (see page 18) when the mark is flashing, an 
information display appears, showing a warning message.
The warning messages can be viewed in any menu except 
the CUE or SET UP menu.
Only one message will be displayed even if there are 
multiple messages. The number of errors appears at the 
lower right, and you can check the messages using the 
and 
r buttons.
 A history of errors is kept in the error log menu.
For more information about warning messages, refer to 
the Maintenance Manual.
Use the displayed warning information to eliminate the 
cause of the warning.
For more information about eliminating the cause of 
warning, refer to the Maintenance Manual.
To automatically display a warning message 
Whenever a warning occurs, change the setting of the VTR 
SETUP menu item 120 “WARNING DISPLAY” to “on”.
12
TAPE TOP ERROR
A tape beginning sensor fault was detected.
13
TAPE END ERROR
A tape end sensor fault was detected.
14
FAN MOTOR ERROR
A cooling fan motor operation fault was detected.
20
CC TIME OVER
A fault was detected in a cassette compartment raising or lowering 
operation.
21
SHIFT TIME OVER
A fault was detected movement of the reel table to adjust for 
cassette size.
22
POSITION BOTH DETECT
The reel table was detected in the L cassette position and S 
cassette position at the same time.
23
THREAD BOTH DETECT
The threading end and unthreading end were detected at the same 
time.
93
DR IF ERROR
A communications error between the SV CPU (board SS-95) and 
drum CPU (board DR-508) was detected.
97
NVRAM CHECK SUM ERROR
An operation fault was detected in the servo system NV-RAM 
(board DR-508).
FF
SV UNDEFINE ERROR
Undefined SV error was detected.
A0
SY UNDEFINE ERROR
Undefined SY error was detected.
A2
SY1-SY2 DPRAM ERROR
A DPRAM (board SS-95) operation fault between SYS1 and SYS2 
was detected.
A5
SY-FC DPRAM ERROR
A DPRAM (board FC-91) operation fault between SYS1 and FC 
was detected.
A8
SY NVRAM CHECK SUM ERROR
A SYS NVRAM (board SS-95) operation fault was detected.
B8
SY1-SY2 INTERFACE ERROR
A SYS CPU communications fault was detected.
B9
SY-SV INTERFACE ERROR
An SV CPU communications fault was detected.
BA
SY-EQ INTERFACE ERROR
An EQ CPU communications fault was detected.
BB
SY-FC INTERFACE ERROR
An FC CPU communications fault was detected.
BC
SY-50PIN INTERFACE ERROR
A communications fault with the 50-pin CPU was detected.
Item number
Display
Meaning
Note