Справочник Пользователя для Sony SRW-5000

Скачать
Страница из 187
155
 Menu List
  
App
end
ix
605
TAPE TIMER 
DISPLAY
+/– 12H
[24H]
Selects whether the CTL counter operates in 12-hour 
display mode or 24-hour display mode.
+/–12H: 12-hour display mode
24H: 24-hour display mode
Note
In the ±12-hour display, the tens digit of the hours value is 
dropped.
606
TCG MODE select
[preset]
regene
auto
Selects the time code to which the internal time code 
generator synchronizes.
preset: By an operation on the front panel or by remote 
control from a device connected to the REMOTE 1-
IN(9P) connector, the initial value of the time code 
generated by the internal time code generator can be 
preset.
regene: The internal time code generator is synchronized 
(“regene”) to the time code values read by the internal 
time code generator.
auto: Operates in regene mode when either assemble or 
insert mode is selected and operates in preset mode 
when any other mode is selected.
607
TCG REGENE 
SOURCE select
SDI-LTC
SDI-VITC
ext-LTC
int-VITC
[int-LTC]
If item 606 is set to “regene”, this selects the source of the 
synchronization of the time code generated internally.
int-LTC: When the time code played back from the time 
code track on the tape is used.
int-VITC: When the time code played back from the “AUX 
data” in the video signal on the tape is used.
ext-LTC: When the external time code input to the TIME 
CODE IN connector is used.
SDI-VITC: When the VITC input to the HD SDI INPUT 
connector is used.
SDI-LTC: When the LTC input to the HD SDI INPUT 
connector is used.
608
TCG/UBG REGENE 
MODE
TC
UB
Selects the regenerate signal when the time code 
generator is in regenerate mode (when item 606 is set to 
“regene”) or during auto edit mode.
TC & UB: The time code signal and user bits signal are 
both regenerated.
TC: The time code signal is regenerated.
UB: The user bits signal is regenerated.
609
REC RUN/FREE 
RUN select
[free run]
rec run
This selects the way in which the time code advances.
free run: Regardless of the operation mode of this unit, the 
time code advances all the time that the power is on.
rec run: The time code advances only during recording. 
Note
When using this setting, set item 606 to “preset”.
610
DOWNCONVERTER 
VICT output
[on]
off
Selects whether or not to insert VITC data in the HD-SD 
converter output.
on: VITC data is inserted.
off: VITC data is not inserted.
611
VITC POSITION-1 
select (NTSC)
12,281 line
   
[16,279 line]
   
20,283 line
When 29.97PsF/59.94i mode is selected on the VTR, this 
setting specifies the lines in which the VITC signal is 
inserted.
It can be inserted in any lines from 12,281 to 20,283.
Note
Items 611 and 612 allow VITC to be inserted in two lines.
Item number
Item
Setting
Function
[TC   UB]
&