S p e c i f i c a t i o n s
A-655
12
SPECIFICATIONS
Size 3655 Series...................7.5" W x 4.0" H x 7.2" D (19.1 cm x 10.2 cm x 18.3 cm)
4650 Series ..............................7" W x 3.8" H x 13" D (18 cm x 10 cm x 33 cm)
5650 Series .......................10.1" W x 10.5" H x 6.5" D (26 cm x 27 cm x 17 cm)
5650 Series .......................10.1" W x 10.5" H x 6.5" D (26 cm x 27 cm x 17 cm)
Weight 3655 Series.....................................................................4.8 lbs. (2.18 kg)
4650 Series.....................................................................5.3 lbs. (2.40 kg)
5650 Series ......................................................................7.1 lbs. (3.2 kg)
5650 Series ......................................................................7.1 lbs. (3.2 kg)
Electrical
Requirements 3655D, 3655T, 4650D & 46502 ...........2.5 amps, 115 VAC (±10%) 60 Hz
Requirements 3655D, 3655T, 4650D & 46502 ...........2.5 amps, 115 VAC (±10%) 60 Hz
3655I & 4650I.................................1.4 amps, 230 VAC (±10%) 50 Hz
3655K & 3655P ................................1.4 amps, 230 VAC (±10%) 60 Hz
5650D, 5650H & 5650C ..................................1.3 amps, 115VAC 60Hz
5650I ..........................................................0.8 amps, 230VAC 50Hz
5650K & 5650P ........................................0.8 amps, 230VAC 50/60Hz
3655K & 3655P ................................1.4 amps, 230 VAC (±10%) 60 Hz
5650D, 5650H & 5650C ..................................1.3 amps, 115VAC 60Hz
5650I ..........................................................0.8 amps, 230VAC 50Hz
5650K & 5650P ........................................0.8 amps, 230VAC 50/60Hz
Sound Level 3655 Series ...........................................................................58 dBA
4650 Series............................................................................53 dBA
5650 Series............................................................................51 dBA
5650 Series............................................................................51 dBA
Power Consumption 3655D, 3655T, 4650D & 46502.....................140 watts maximum
3655I, 3655K, 3655P & 4650I .....................160 watts maximum
5650D, 5650H & 5650C ................................90 watts maximum
5650I, 5650K & 5650P ...............................100 watts maximum
5650D, 5650H & 5650C ................................90 watts maximum
5650I, 5650K & 5650P ...............................100 watts maximum
Maximum Compressor Pressure 3655 & 4650 series .......35 psig or greater (241 kPa)*
5650 series ..................30 psig or greater (206 kPa)*
Compressor Free Air Flow 3655 & 4650 ........................................8 lpm or greater*
5650 ...................................................9 lpm or greater*
Operating
Temperature Range all Models except 5650C ................+40° to +104°F (+5 to +40°C)
Temperature Range all Models except 5650C ................+40° to +104°F (+5 to +40°C)
5650C ......................................+40° to +101°F (+5 to +38.5°C)
Operating Humidity all Models .......................................up to 95% non-condensing
Storage/Transport Temperature Range all Models ......-40° to +158°F (-40° to +70°C)
Storage/Transport Humidity all Models............................up to 95% non-condensing
Supplied Nebulizer Capacity all models....................................................6 ml (cc)
Supplied Nebulizer Nebulization Rate all models.......................0.15 ml/min or greater*
Supplied Nebulizer MMAD all models .........................................5 microns or less**
Storage/Transport Temperature Range all Models ......-40° to +158°F (-40° to +70°C)
Storage/Transport Humidity all Models............................up to 95% non-condensing
Supplied Nebulizer Capacity all models....................................................6 ml (cc)
Supplied Nebulizer Nebulization Rate all models.......................0.15 ml/min or greater*
Supplied Nebulizer MMAD all models .........................................5 microns or less**
*Conditions may vary based on altitude above sea level, barometric pressure, and temperature.
**Value determined with minimum flow rate through the nebulizer (20°C, sea level).
**Value determined with minimum flow rate through the nebulizer (20°C, sea level).
There are no hazardous materials used in the construction of this unit, therefore, there
are no known risks associated with disposal of the equipment.
are no known risks associated with disposal of the equipment.
This product (models 3655D & 3655T) complies with the following electromagnetic
compatibility standard: IEC 60601-1-2:2nd Edition
compatibility standard: IEC 60601-1-2:2nd Edition
3655D & 3655T Equipment Classifications:
Protection against electric shock:................................................................Class II
Degree of protection against electric shock: .................................................Type BF
Equipment not suitable for use in the presence of flammable anaesthetic mixture with
air or with oxygen or nitrous oxide
Mode of operation:.................................................................Continuous operation
Protection against electric shock:................................................................Class II
Degree of protection against electric shock: .................................................Type BF
Equipment not suitable for use in the presence of flammable anaesthetic mixture with
air or with oxygen or nitrous oxide
Mode of operation:.................................................................Continuous operation