Справочник Пользователя для Intermate AS/400

Скачать
Страница из 490
158
    User’s Manual for InterForm400
®
          Update AFC-functions attatched to output queues              AFC305D  
                                                                                
 Output queue . . . . . . :   AFC_INPUT1                                        
   Library  . . . . . . . :     APF3812                                         
 Seqnbr Funct   Form type  Save Jobname    Filename   Device file  Program      
  0001    1     DEMO                                                            
                Merge, Overlay: IF400DEMO Fileset: SAMPLE                       
  0002    6                                                                     
                Hold Spooled File                                               
                                                                                
                                                                                
                                                                                
                                                                                
 Seqnbr Function                                                                
   0,1    5        Move Spooled File                                            
                                                                                
                   New output queue . . . . . . . .  AFC_OUT1__    *DEFAULT, *USER 
                     Library  . . . . . . . . . . .    APF3812___                  
                   Hold output spooled file . . . .  *NO_          *NO, *YES    
                   Save output spooled file . . . .  *NO_          *NO, *YES    
                                                                                
                                                                                
                                                                                
 F3=Exit           F13=Fold/Unfold                           F12=Cancel         
We want to send all spool entries with formtype *STD to the output queue AFC_OUT1
without adding any overlay. When we press Enter, we see the AFC function appear as the
first line:
          Update AFC-functions attatched to output queues              AFC305D  
                                                                                
 Output queue . . . . . . :   AFC_INPUT1                                        
   Library  . . . . . . . :     APF3812                                         
 Seqnbr Funct   Form type  Save Jobname    Filename   Device file  Program      
  0001    5     *STD                                                            
                Move spooled file, new outq: AFC_OUT1 library: APF3812          
  0002    1     DEMO                                                            
                Merge, Overlay: IF400DEMO Fileset: SAMPLE                       
  0003    6                                                                     
                Hold Spooled File                                               
                                                                                
                                                                                
 Seqnbr Function                                                                
   0,1                                                                          
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
 F3=Exit             F5=Service        F13=Fold/Unfold                          
Step 5. Defining move of Print jobs with Formtype DEMO
Currently sequence line 3 defines that all files should be put on hold when they have been
processed by line 1 and 2.
This means that currently the sample spool entry with form type DEMO is put on hold and
stays in the queue. We now want to move this type of spool file to queue AFC_INPUT2,
so it can be processed by the AFC definition for that queue.
We enter a sequence line between sequence line 2 and 3, meaning that we will move the
demo spool entry, after it has been used to create a merged spool file on queue
AFC_OUT1, but before it would get put on hold by sequence line 3:
We enter sequence line 2,1 and press Field Exit. We enter form type DEMO as the
criteria for executing the move operation and we press Enter: