?, Return the Value of the Last Updated S-register
This command displays the most recently updated value stored in an S-register.
Example
AT?
000
OK
AT?
003
OK
ATS36=5
OK
AT?
005
OK
&F, Set to Factory Defined Configuration
This command restores the factory default configuration profile. The G24 only supports one
factory default profile, 0.
factory default profile, 0.
The following table shows the &F parameters.
Command Type
Syntax
Response/Action
Remarks
Read
AT?
000
OK
The Read command returns the value
of the last updated S-register.
of the last updated S-register.
Command Type
Syntax
Response/Action
Remarks
Set
AT&F<value>
OK
or:
+CMS ERROR: <err>
Read
AT&F?
<current profile
number>
Test
The Test command for &F is not
defined by ITU, and therefore is not
supported by the G24. The G24 returns
an error.
defined by ITU, and therefore is not
supported by the G24. The G24 returns
an error.
Table 3-187: &F Parameters
<Parameter>
Description
<value>
0
Factory default configuration profile. This is the only value supported.