Справочник Пользователя для Motorola MC65

Скачать
Страница из 212
11 - 8 MC65 User Guide
Single Slot USB Cradle
Table 11-3    
Troubleshooting the Single Slot USB Cradle
Symptom
Possible Cause
Action
LEDs do not light 
when MC65 or spare 
battery is inserted.
Cradle is not 
receiving power.
Ensure the power cable is connected securely to both the cradle 
and to AC power.
MC65 is not seated 
firmly in the cradle.
Remove and re-insert the MC65 into the cradle, ensuring it is firmly 
seated. 
Spare battery is not 
seated firmly in the 
cradle.
Remove and re-insert the spare battery into the charging slot, 
ensuring it is firmly seated. 
MC65 battery is not 
charging.
MC65 was 
removed from 
cradle or cradle 
was unplugged 
from AC power too 
soon.
Ensure cradle is receiving power. Ensure MC65 is seated 
correctly. Confirm main battery is charging under Tap Status Bar 
. The 3600 mAh battery fully charges in less than six hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty 
battery.
The MC65 is not 
fully seated in the 
cradle.
Remove and re-insert the MC65 into the cradle, ensuring it is firmly 
seated. 
Extreme battery 
temperature.
Battery does not charge if ambient temperature is below 0°C 
(32°F) or above 40°C (104°F).
Spare battery is not 
charging.
Battery not fully 
seated in charging 
slot. 
Remove and re-insert the spare battery in the cradle, ensuring it is 
firmly seated. 
Battery inserted 
incorrectly. 
Re-insert the battery so the charging contacts on the battery align 
with the contacts on the cradle. 
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty 
battery.
During data 
communication, no 
data transmits, or 
transmitted data was 
incomplete.
MC65 removed 
from cradle during 
communications.
Replace MC65 in cradle and retransmit.
Communication 
software is not 
installed or 
configured properly.
Perform setup as described in the MC65 Integrator Guide.