Справочник Пользователя для American Standard 7056.115

Скачать
Страница из 9
3
Fig. 2
    MAKE WATER SUPPLY
CONNECTIONS; Fig. 2
3
    INSTALL OPTIONAL MIXING
VALVE; Fig. 3
4
1. Turn off hot and cold water supplies before 
beginning.
2. Connect HOSE ADAPTERS (3) to wall supplies (if 
required). Connect FLEXIBLE SUPPLIES 
(1, 2) directly 
to HOSE ADAPTERS 
(3)
3.  Connect left supply (Marked with a Red Stripe) to 
Hot and right supply (Marked with Blue Stripe) to Cold 
supply. Use adjustable
wrench to tighten connections. Do not over tighten.
4. Faucet supplies are 18" long from faucet base.
Note; If additional supply length is required, 
installer must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long, 
loop as illustrated to avoid kinking.
Fig. 3
Fig. 1
M965255 REV. 1.6
1
2
3
COLD
HOT
Note; For complete detailed installation and 
operating instructions see installations 
instructions supplied with mixing valve.
No. M968808
 
For 7055.105/115 & 7056.105/115 Faucets.
Installation Instr
uctions
In
s
ta
ll
a
ti
o
n
 I
n
s
tr
u
c
ti
o
n
s
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Thermostatic Mixing Valve
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
To learn more about American Standard Faucets visit our website at: 
www.us.amstd.com or U.S.
customer's e-mail us at: 
faucetsupport@amstd.com
For Parts, Service, Warranty or other Assistance,
please call 
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
605XTMV
Specifications
Installation
Adjust Temperature
Service
Replacement Parts
1
2
3
3
4
No. M968808
MAINTENANCE
When the Sensor detects a user, the water 
immediately starts to flow. Water flow will stop two 
seconds after user is out of sensor range. The off delay 
allows the user to comfortably move his hands without 
the flow cycling on to off. As a precaution, a safety 
timer will turn off the water, after the sensor has been 
blocked for 59 seconds. The water will stay off until the 
blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50.8mm - 254mm)
Default: Set at Factory 6" (152.4mm)
    HAND WASH SENSOR OPERATION;
Fig. 1
1
DETECTION
ZONE
REMOVE PROTECTIVE FILM FROM SENSOR EYE
WHEN INSTALLATION IS COMPLETE.
PROTECTIVE FILM
SEAL
WASHER
(SUPPLIED)