6.13.2 Change of time constants 
After rewriting the time constant, turning the change time constant signal (TACHG, TDCHG) on causes the 
time constant to change. Time constants can be designated separately as the acceleration time constant and 
the deceleration time constant. 
For automatic operation and linear interpolation operation rewrite the time constant in the operating point table 
and for JOG operation and incremental feed, rewrite the manual feed time constant. 
Change acceleration 
time constant (TACHG)
Completion of preparations 
for changing acceleration 
time constant (TACF)
ON
OFF
Start operation (ST)
ON
OFF
ON
OFF
Acceleration time constant 2
Acceleration time constant 1
Speed limit value
Command speed
Acceleration time constant 2
Acceleration time constant 1
 
During the following cases, the "acceleration time constant change error signal" (TACE) or the "deceleration 
time constant change error signal" (TDCE) turns on, and time constant will not change. 
• Operation stop 
• Deceleration 
• Home position return 
• Home position reset 
 
 
API LIBRARY  
Use the sscChangeAutoAccTime or sscChangeAutoDecTime functions to 
perform a change of time constants for automatic operation and linear 
interpolation operation. 
Use the sscChangeManualAccTime or sscChangeManualDecTime functions 
to perform a change of time constants for JOG operation and incremental 
feed.