Справочник Пользователя для Mitsubishi Electronics MR-MC210

Скачать
Страница из 658
 
 
7 - 87 
7. AUXILIARY FUNCTION 
 
7.13.5 Log function interface 
(1) Command/status bit 
System command/status bits related to log function are shown below. 
 
System command 
 
System status 
Address Bit Abbreviation 
Signal 
name 
  Address
Bit
Abbreviation
Signal 
name 
03EA 0  LOGC Log 
command 
 
045A 0
LOGO 
Log operation being 
performed 
 
LOGR 
Reading of log data command
 
 
1
LOGRF 
Reading of log data complete
 2 
 
Reserved 
 
 
2
LOGRE 
Reading of log data error 
 3 
LOGI 
Log data initialization 
command 
  
3
LOGIF 
Log data initialization is 
complete 
 
 
 
 
 
4
LOGIE 
Log data initialization error 
 5 
Reserved 
 
 
5
 
 
 6 
 
 6
Reserved 
 7 
 
 
 7
 
 
(a) Details concerning system command bits 
 
Abbreviation Signal 
name 
Function 
details 
LOGC Log 
command 
[Function] 
Starts/stops recording of log data. 
[Operation] 
When the log command signal (LOGC) is turned on, recording of log data is started, 
and log operation being performed signal (LOGO) is turned on. The log operation 
being performed signal (LOGO) is turned off when the log command signal (LOGC) is 
turned off. 
LOGR 
Reading of log data 
command 
[Function] 
Reads the log data stored in the log data buffer area to the log data table on the dual 
port memory. 
[Operation] 
When the reading of log data command signal (LOGR) is turned on, the log data for 
the page number set as the read log data page number is read into the log data table. 
When reading of log data is complete, the reading of log data complete signal 
(LOGRF) is turned on or a reading of log data error signal (SMPRE) is turned on. 
LOGI Log 
data 
initialization 
command 
[Function] 
Initialization of the log data stored in the log data buffer area. 
[Operation] 
When the log data initialization command signal (LOGI) is turned on, the log data is 
initialized and the number of valid log data events and time stamp are 0 cleared.