12 - 12 
12. MONITOR NUMBER 
 
12.5 System information 
Monitor No. 
Content 
Units 
Remarks 
0400 Reserved 
 
 
0401 
Cause of forced stop (Note) 
 
bit 0: External forced stop 
bit 1: Software forced stop 
bit 2: User watchdog 
bit 3: Communication error 
bit 4: An axis that has not been mounted exists 
bit 5: During reboot preparation 
bit 6: System error E5    occurrence 
0402 
Reserved  
 
0403 
0404 
0405 
0406 
0407 
0408 
0409 
040A Parameter 
backup 
times 
Times 
Displays the times of write accesses to flash ROM by the 
parameter backups after system preparation is completed. 
040B 
Reserved  
 
040C 
040D 
040E 
040F 
0410 
System parameter error number 
No. 0001 to 000F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0001 (bit 1) to 000F (bit 15). 
0411 
System parameter error number 
No. 0010 to 001F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0010 (bit 0) to 001F (bit 15). 
0412 
System parameter error number 
No. 0020 to 002F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0020 (bit 0) to 002F (bit 15). 
0413 
System parameter error number 
No. 0030 to 003F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0030 (bit 0) to 003F (bit 15). 
0414 
System parameter error number 
No. 0040 to 004F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0040 (bit 0) to 004F (bit 15). 
0415 
System parameter error number 
No. 0050 to 005F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0050 (bit 0) to 005F (bit 15). 
0416 
System parameter error number 
No. 0060 to 006F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0060 (bit 0) to 006F (bit 15). 
0417 
System parameter error number 
No. 0070 to 007F 
 
Bit corresponding to parameter number is turned on. 
bit is No. 0070 (bit 0) to 007F (bit 15). 
0418 
Reserved  
 
047F 
Note. The bit for the corresponding forced stop factor is turned on.