Справочник Пользователя для Mitsubishi Electronics MR-MC210

Скачать
Страница из 658
 
 
 
App. - 32 
APPENDIX 
 
App. 5.6 Axis No. setting 
Axis No. is set by the axis selection rotary switch (Note). The axis No. and rotary switch No. are correlated as 
shown on the table below. Set the axis No. of the servo amplifier so that it will not duplicate in the same 
SSCNET line. If it is duplicated, the "An axis that has not been mounted exists" (system error E400) will occur 
at the time of system startup (system command code: 000Ah). 
 
Note. The name and setting method of the axis selection rotary switch vary depending on the unit device to 
be used. For details, refer to the unit device specification for your unit. 
 
 
App. 5.6.1 Servo amplifier setting 
(1) MR-J3(W)- B 
Axis No. of MR-J3(W)- B is set by the axis selection rotary switch (SW1) on the servo amplifier. Servo 
amplifier axis No. and rotary switch setting are correlated as shown on the table below. Set the axis No. of 
the servo amplifier so that it will not duplicate in the same line. If it is duplicated, the "An axis that has not 
been mounted exists" (system error E400) will occur at the time of system startup (system command code: 
000Ah). 
 
Servo 
amplifier 
axis No. 
Axis selection rotary 
switch 
Servo amplifier display 
(3-digit, 7-segment indicator)
d1 0 
01 
d2 1 
02 
d3 2 
03 
d4 3 
04 
d5 4 
05 
d6 5 
06 
d7 6 
07 
d8 7 
08 
d9 8 
09 
d10 9 
10 
d11 A 
11 
d12 B 
12 
d13 C 
13 
d14 D 
14 
d15 E 
15 
d16 F 
16 
 
 
POINT 
 
For each switch setting, refer to the Servo Amplifier Instruction Manual for 
your servo amplifier. 
If the "An axis that has not been mounted exists" (system error E400) 
occurred, the axis with wrong axis No. set can be confirmed with "information 
concerning axis that is not mounted" (monitor No.0480 to 0482). 
The servo amplifier axis No. and the axis No. to be managed on the position 
board are different. For details, refer to App. 5.9.