App. 5.11 Vendor ID and type code setting 
Available functions, parameter settings and ranges will vary by servo amplifier type. At the time the 
communication with the servo amplifier has started, the position board will perform consistency check between 
type code of the servo amplifier connected and the parameter set. If a consistency check error occurs, driver 
type code error (system error E405) will be output, therefore set correct type code. 
 
POINT 
 
If driver type code error (system error E405) occurred, the axis that has set an 
incorrect type code can be confirmed with "type code erroneous axis 
information" (monitor No.0484 to 0486). 
When the communication method is SSCNET , driver type code error 
(system error E405) due to the inconsistency of vendor IDs. 
 
 
(a) Control parameters 
 
Parameter 
No. 
Abbreviation Name 
Function 
021D 
*VEND 
Vendor ID 
Set the vendor ID. 
0000: Mitsubishi Electric 
Note. Not used in SSCNET  communication. 
021E 
*CODE 
Type code 
Set the type code. 
0100: MR-J3-B, MR-J3W-B (for rotary servo motor) 
0101: MR-J3-BS, MR-J3-B-RJ006 
0102: MR-J3-B-RJ004, MR-J3W-B (for linear servo motor) 
0107: MR-J3-B-RJ080W 
0180: MR-J3W-0303BN6 
 
 
App. 5.12 System startup processing 
The parameter settings and the system startup processing is the same as those of when the SSCNET 