Справочник Пользователя для Mitsubishi Electronics MR-MC210

Скачать
Страница из 658
 
 
 
App. - 46 
APPENDIX 
 
App. 5.14.1 Application functions 
(1) Gain changing 
For the usage of gain changing, which is the same as that of the servo amplifier MR-J4(W )- B, refer to 
Section 6.19. However, for the servo parameters to be used, refer to the following table. 
 
Servo parameters (MR-J3(W)- B) 
 
Parameter No. 
MR-J3(W)-B  
Parameter No. 
Symbol Name 
Setting 
0139 PB26 
*CDP 
Gain 
changing 
selection 
0001 (valid when command received 
from controller and when the input signal 
(CDP) is on) 
013A PB27 
CDL 
Gain 
changing 
condition 
013B 
PB28 
CDT  Gain changing time constant 
Arbitrary within  setting range 
013C PB29 
GD2B 
Gain changing ratio of load inertia moment to 
servo motor inertia moment 
Arbitrary within setting range 
013D 
PB30 
PG2B  Gain changing position loop gain 
Arbitrary within setting range 
013E 
PB31 
VG2B  Gain changing speed loop gain 
Arbitrary within setting range 
013F 
PB32 
VICB  Gain changing speed integral compensation 
Arbitrary within setting range 
0140 PB33 
VRF1B 
Gain changing vibration suppression control 
vibration frequency setting 
Arbitrary within setting range 
0141 PB34 
VRF2B 
Gain changing vibration suppression control 
resonance frequency setting 
Arbitrary within setting range 
 
POINT 
 
Refer to the Servo Amplifier Instruction Manual on your servo amplifier 
concerning details for the servo parameters. 
To use the gain switching function, first set the gain adjustment mode to a 
manual mode by changing an auto-tuning mode (parameter No.0107) to 3 
(manual mode). If the gain adjustment mode is in an auto-tuning mode, the 
gain changing function cannot be used. 
 
(2) PI-PID switching 
For the usage of PI-PID switching, which is the same as that of the servo amplifier MR-J4(W )- B, refer 
to Section 6.20. However, for the servo parameters to be used, refer to the following table. 
 
Servo parameter (MR-J3(W)- B) 
 
Parameter No. 
MR-J3(W)-B 
Parameter No. 
Abbreviation Name 
Setting 
value 
0137 
PB24 
*MVS 
Slight vibration suppression control selection
   0   (PI control is valid (can be 
switched to PID control by the command 
from the controller).) 
 
POINT 
 
Refer to the Servo Amplifier Instruction Manual on your servo amplifier 
concerning details for the servo parameters. 
To use the PI-PID switching function, first set the gain adjustment mode to a 
manual mode by changing an auto-tuning mode (parameter No.0107) to 3 
(manual mode). If the gain adjustment mode is in an auto-tuning mode, the 