Справочник Пользователя для Mitsubishi Electronics Q01UCPU

Скачать
Страница из 212
80
4.2.2
Parameter settings
This section describes parameters required for the system configuration on Page 79, Section 4.2.1. Use 
programming tool to set parameters.
 • Settings of parameters in double-lined squares on Page 77, Section 4.2 (1) must be the same in all the CPU 
modules in a multiple CPU system.
 • The necessity of parameters differs depending on the QCPU used. (
(1) Setting parameters (for the first time)
1.
Set "Points Occupied by Empty Slot" in the "PLC System" window of PLC parameter.
Project window 
 [Parameter] 
 [PLC Parameter] 
 [PLC System] 
 "Points Occupied by 
Empty Slot"
2.
Set parameters for the multiple CPU system in the "Multiple CPU Setting" window of PLC 
parameter.
Project window 
 [Parameter] 
 [PLC Parameter] 
 [Multiple CPU Setting]
Item
Description
Default
Points Occupied by Empty Slot
Set the number of points occupied by one empty slot.
16 points