6. APPLICATION FUNCTIONS 
 
6.29.3 Interface 
(1) Pass position interrupt table 
The pass position condition (pass position option and pass position data) is set to the pass position 
interrupt table. 
The pass position condition is imported when the corresponding pass position condition number is started 
to be judged. 
 
POINT 
 
When the pass position condition setting is incorrect, a pass position interrupt 
error (operation alarm 5C, detail 04) occurs and the operation is stopped. 
 
API LIBRARY  
Use the sscSetIntPassPositionData/sscCheckIntPassPositionData functions 
to set/get pass position interrupt data. 
 
 
Pass position interrupt table 
 
A640h 
Pass position condition 1 
(8 bytes) 
Pass position option 
 
Pass position data 
A648h 
Pass position condition 2 
(8 bytes) 
Pass position option 
 
Pass position data 
A650h 
Pass position condition 3 
(8 bytes) 
Pass position option 
 
Pass position data 
A658h 
Pass position condition 4 
(8 bytes) 
Pass position option 
 
Pass position data 
A660h 
Pass position condition 5 
(8 bytes) 
Pass position option 
 
Pass position data 
A668h 
Pass position condition 6 
(8 bytes) 
Pass position option 
 
Pass position data 
A670h 
Pass position condition 7 
(8 bytes) 
Pass position option 
 
Pass position data 
A678h 
Pass position condition 8 
(8 bytes) 
Pass position option 
 
Pass position data 
A680h 
Pass position condition 9 
(8 bytes) 
Pass position option 
 
Pass position data 
A688h 
Pass position condition 10 
(8 bytes) 
Pass position option 
 
Pass position data 
A690h 
Pass position condition 11 
(8 bytes) 
Pass position option 
 
Pass position data 
A698h 
Pass position condition 12 
(8 bytes) 
Pass position option 
 
Pass position data 
A6A0h 
Pass position condition 13 
(8 bytes) 
Pass position option 
 
Pass position data 
 : 
A838h 
Pass position condition 64 
(8 bytes) 
Pass position option 
A83Fh 
Pass position data