Справочник Пользователя для Mitsubishi Electronics MR-MC211
5 - 4
5. OPERATIONAL FUNCTIONS
5.2 Incremental feed
5.2.1 Summary
A prescribed feed amount is implemented for each fast start operation signal (FST). The feed amount is
defined using the incremental feed movement amount.
Incremental feed can be used without completing home position return (home position return request (ZREQ)
is ON).
defined using the incremental feed movement amount.
Incremental feed can be used without completing home position return (home position return request (ZREQ)
is ON).
sscWaitIntDriveFin function/
sscGetDriveFinStatus function
sscGetDriveFinStatus function
sscIncStart function
After moving the movement amount
designated as the incremental feed
movement amount, it stops.
designated as the incremental feed
movement amount, it stops.
Speed
Start of operation
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
Fast Start operation
(FST)
(FST)
Incremental feed
mode (S)
mode (S)
Completion of
operation (OPF)
operation (OPF)
Movement direction
(DIR)
(DIR)