5. OPERATIONAL FUNCTIONS 
 
5.4 Linear interpolation 
5.4.1 Summary 
Linear interpolation operation has interpolation control performed for the axes set up as a group. This system 
enables a maximum of 4 axis interpolation control. When the feed speed and position data are defined in the 
point table and the fast start operation signal (FST) is input, all of the axes setup in the group perform linear 
interpolation operation. If linear interpolation operation is started prior to completion of home position return 
(home position return request (ZREQ) is ON), a home position return not complete error (operation alarm 90, 
detail 01) occurs upon starting operation and the operation stops. 
Afterwards, the fast start operation signal (FST) is input on a primary axis and other axes are referred to as 
auxiliary axes. 
ON
OFF
0
1
2
0
Start of operation
ON
OFF
ON
OFF
ON
OFF
ON
OFF
sscLinearStart function
sscWaitIntDriveFin function/
sscGetDriveFinStatus function
Stops after moving
to the end point
position.
Primary axis
completion of
operation (OPF)
Primary axis
fast Start operation
(FST)
Primary axis
operation point number
Auxiliary axis
linear interpolation
mode signal (LIP)
Primary axis 
linear interpolation
mode signal (LIP)
Primary axis
positioning complete
 (PF)
Auxiliary axis speed
Primary axis speed
 
 
 
POINT 
 
The group setting is set using the linear interpolation group (parameter 
No.0260). If the group number is set to 0, the axis becomes an independent 
axis, making it so linear interpolation operation can not be performed. The 
number of groups that can be defined differs with the control cycle and the 
maximum number of groups is 8. 
 
Control cycle 
Valid group number  
 0.88 
ms 
to 
 
 0.44 
ms 
to 
 
 0.22 
ms 
 
 
The fast start operation signal (FST) is only to be input on a primary axis.