6 - 5 
6. APPLICATION FUNCTIONS 
 
6.2 Speed unit 
The speed command (feed speed of point table, manual feed speed, etc) is set by the speed unit. Speed units 
are adjusted using the speed units and the speed units multiplication factor (parameter No.020E, 020F) of the 
control option 1 (parameter No.0200). Through changing the speed units, movement can be performed at an 
arbitrary unit and multiplication of speed. 
 
API LIBRARY  
Use the sscChange2Parameter/sscCheck2Parameter functions to set/get 
speed unit. 
 
 
6.2.1 Settings 
Control parameters 
Parameter No. 
(Note) 
Abbreviation
Name 
Initial 
Value
Unit 
Setting 
range
Function 
0200 
*OPC1 
Control option 1 
0001h
 
0000h to 
2111h
Control axis
No home position
Speed unit
Set the speed command unit.
0: Position command unit/min
1: Position command unit/s
2: r/min
Amplifier-less axis function
020E SUML 
Speed 
units 
multiplication factor 
(lower) 
2000h
 1 
to 
32768
(32 bit)
Set the speed command multiplication. 
020F SUMH 
Speed 
units 
multiplication factor 
(upper) 
0000h
 