7 - 37 
7. AUXILIARY FUNCTION 
 
7.11.5 Reconnection method 
SSCNET communication reconnection is executed by turning on the reconnection command. The axis number 
to be connected axis is not needed to be specified. 
The flowchart of the reconnection is shown below. 
 
sscReconnectSSCNET function
No
Yes
Turn off the reconnection
command (RCC).
Turn on the reconnection
command (RCC).
No
START
Reconnection
complete (RCF)
ON?
Reconnection
error (RCE) ON?
Error processing
Yes
Confirm the reconnected
axis with the controlling
axis information.
END