Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
7 - 43 
7. AUXILIARY FUNCTION 
 
7.12.3 Command/status data 
The system command/status data related to the sampling function are shown below. 
 
(1) Sampling setting write (command) 
 
Address Name Setting 
range
Remarks 
BDA0 Sampling 
setting 
 
write number 
0000h to 
00AFh 
Set the sampling setting number to be written. 
Note. For 0000h, sampling setting number error does not occur. 
BDA1 
BDA2 Reserved 
 
 
BDA3 
BDA4 Sampling 
setting 
 
write data 
00000000h to 
FFFFFFFFh
Set the data of the sampling setting number to be written. 
BDA5 
BDA6 
BDA7 
 
(2) Sampling setting write (status) 
 
Address Name Output 
limits
Remarks 
BDA8 Sampling 
setting 
 
write number 
0000h to 
FFFFh 
Displays the sampling setting number which was written. 
BDA9 
BDAA Reserved 
 
 
BDAB 
BDAC Sampling 
setting 
 
write data 
00000000h to 
FFFFFFFFh
Displays the data of the sampling setting number which was written. 
BDAD 
BDAE 
BDAF 
 
(3) Sampling setting read (command) 
 
Address Name Setting 
range
Remarks 
BDB0 Sampling 
setting 
 
read number 
0000h to 
00AFh 
Set the sampling setting number to be read. 
Note. For 0000h, sampling setting number error does not occur. 
BDB1 
BDB2 Reserved 
 
 
BDB3 
BDB4 
BDB5 
BDB6 
BDB7 
 
(4) Sampling setting read (status) 
 
Address Name Output 
limits
Remarks 
BDB8 Sampling 
setting 
 
read number 
0000h to 
FFFFh 
Displays the sampling setting number which was read. 
BDB9 
BDBA Reserved 
 
 
BDBB 
BDBC Sampling 
setting 
 
read data 
00000000h to 
FFFFFFFFh
Displays the data of the sampling setting number which was read. 
BDBD 
BDBE 
BDBF