Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
7 - 90 
7. AUXILIARY FUNCTION 
 
7.13.6 Timing chart for reading of log data 
A method for reading log data stored in the log data buffer area is shown below. 
ON
OFF
sscReadLogData function
Page 1
Page 2
Page 3
ON
OFF
Reading of log data
command (LOGR)
Log data read page
number
Reading of log data
complete (LOGRF)
 
 
POINT 
 
For reading of log data, turn off the log command signal (LOGC). If log data is 
read while the log operation being performed signal (LOGO) is turned on, the 
reading of log data error (LOGRE) is turned on. 
Log data is stored using a ring buffer format in the log data buffer area of the 
position board; however, when transferred to the dual port memory, the data 
is transferred from the oldest (oldest is transferred first) in order. 
 
 
7.13.7 Log acquiring selection 
By setting the log acquiring selection (parameter No.0040 to 0042), the axis No. and system for which the log 
to be acquired can be set. 
When the number of log events to be memorized is not enough, set the events (axis and system) for which log 
is to be acquired, using this function. 
 
(1) System parameter 
 
Parameter No.  Abbreviation 
Name 
Initial value
Unit
Setting 
range 
Function 
0040 LGS1 
Log 
acquiring 
selection 1 
(Note 1) 
0000h 
 
0000h to 
0001h 
Set whether to acquire the log of the system 
when the log function is used. 
System (bit 0) 
0: Not acquire   1: Acquire 
0041 LGS2 
Log 
acquiring 
selection 2 
(Note 1) 
0000h 
 
0000h to 
FFFFh 
Set the axis number for which the log is to be 
acquired. 
Axis 1 (bit 0) to axis 16 (bit 15) 
0: Not acquire   1: Acquire 
0042 LGS3 
Log 
acquiring 
selection 3 
(Note 1) 
0000h 
 
0000h to 
FFFFh 
Set the axis number for which the log is to be 
acquired. 
Axis 17 (bit 0) to axis 32 (bit 15) 
0: Not acquire   1: Acquire 
 
Note 1. When all the system parameters of the log acquiring selection (parameters No. 0040 to 0042) are set to 0000h (initial value), 
log for all axes and systems will be acquired. 
2. Since the parameter for the log acquiring selection is not determined before the system startup, log for all axes and systems will 
be acquired.