7 - 98 
7. AUXILIARY FUNCTION 
 
7.17.2 Alarm history data details 
There are three types of history data, system startup command data and completion of system startup data, 
and alarm history data. One history data is 64 bytes. The details of the data are shown in the following. 
 
(1) System startup command data 
 
 
Offset Content 
 
Offset Content 
0000h 
System startup time 
 0020h 
Reserved 
0001h  
0021h 
0002h  
0022h 
0003h  
0023h 
0004h  
0024h 
0005h  
0025h 
0006h  
0026h 
0007h  
0027h 
0008h 
Free run counter 
 0028h 
0009h  
0029h 
000Ah  
002Ah 
000Bh  
002Bh 
000Ch Control 
cycle 
 
002Ch 
000Dh Event 
code 
 
002Dh 
000Eh 
Reserved 
 002Eh 
000Fh  
002Fh 
0010h Communication 
mode 
 
0030h 
0011h Control 
mode 
 
0031h 
0012h 
Reserved 
 0032h 
0013h  
0033h 
0014h  
0034h 
0015h  
0035h 
0016h  
0036h 
0017h  
0037h 
0018h  
0038h 
0019h  
0039h 
001Ah  
003Ah 
001Bh  
003Bh 
001Ch  
003Ch 
001Dh  
003Dh 
001Eh  
003Eh 
001Fh  
003Fh 
Checksum 
 
(a) System startup time 
When the API library is used, the number of seconds passed since 0000hrs, January 1, 1970 at the 
input time for system startup command is stored. 
When the API library is not used, "0" is stored. 
 
(b) Free-run counter 
Stores the value of the free-run counter at the system startup command.