Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
7 - 103 
7. AUXILIARY FUNCTION 
 
7.17.3 Interface 
(1) System Command/Status Bit 
System command/status bits related to alarm history function are shown below. 
 
System command 
 
System status 
Address Bit Abbreviation 
Signal 
name 
  Address
Bit
Abbreviation
Signal 
name 
03E1 0  SMPS Sampling 
start 
 
0451 0
SMPW Waiting 
for 
sampling 
trigger 
 1 
 
Reserved 
 
 
1
SMPO 
Sampling is being performed 
 2 
 
 2
SMPF 
Sampling 
is 
complete 
 3 
 
 3
SMPE 
Sampling 
Error 
 4 
 
 4
 
Reserved 
 
 
 
5
AHINF 
Alarm history information 
 6 
 
 6
 
Reserved 
 7 
 
 7
 
System command 
 
System status 
Address Bit Abbreviation 
Signal 
name 
  Address
Bit
Abbreviation
Signal 
name 
03F7 
ALHR 
Alarm history read command 
 
0467 
0
ALHRF 
Alarm history read complete 
 
 
Reserved 
 
 
1
ALHRE 
Alarm history read error 
 2 
ALHI 
Alarm history initialization 
command 
 
 
2
ALHIF 
Alarm history initialization 
complete 
 3 
 
Reserved 
 
 
3
ALHIE 
Alarm history initialization 
error 
 4 
 
 4
 
Reserved 
 5 
 
 5
 6 
 
 6
 7 
 
 7
 
(a) Details concerning system command bits 
 
Abbreviation Signal 
name 
Function 
details 
ALHR 
Alarm history read 
command 
[Function] 
Reads the alarm history stored in the alarm history buffer area (flash ROM) to the 
alarm history table on the dual port memory. 
[Operation] 
When the alarm history read command signal (ALHR) is turned on, the alarm history 
for the page number set as the alarm history read page number is read to the alarm 
history table. When reading of alarm history is complete, the alarm history read 
complete signal (ALHRF) is turned on or alarm history read error signal (ALHRE) is 
turned on. 
ALHI Alarm 
history 
initialization command 
[Function] 
Initialization of the alarm history stored in the alarm history buffer area(flash ROM) 
[Operation] 
When the alarm history initialization command signal (ALHI) is turned on, the alarm 
history is initialized and the number of valid alarm history events are 0 cleared.