Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
7 - 107 
7. AUXILIARY FUNCTION 
 
7.17.5 Alarm history initialization procedure 
The procedure for initialization of parameters are as follows. 
Yes
sscClearAlarmHistoryData function
End
No
Note. Set E15A to the alarm history initialization ID.
Turn off alarm history
initialization command (ALHR)
Alarm history initialization ID
setting
Turn on alarm history
initialization command (ALH)
Start
Alarm
history initialization
complete?
 
 
POINT 
 
Do not turn off the power supply to the position board during initialization of 
alarm history. 
Alarm history data cannot be read during initialization of alarm history. 
 
API LIBRARY  
Use the sscClearAlarmHistoryData function to initialize alarm history. 
 
 
7.17.6 List of system errors that do not apply to alarm history storage 
System errors that do not apply to alarm history storage are shown below. 
 
Error code 
Content 
E001 ROM 
error 
E002 
RAM error 1 
E003 Dual 
port 
memory 
error 
E004 
RAM error 2 
E006 
SSCNET communication IC error 1 
E007 
SSCNET communication IC error 2 
E008 Board 
error 
E1
 CPU 
error 
EF01 
System command code error