App. - 55 
APPENDIX 
 
App. 5.16 Parameters 
Concerning the parameters for which the parameter name shows that it is set by manufacturer, do not use 
other than the default values. If erroneous values are set, unexpected movement can occur. 
The parameters are classified as is shown below. 
When using the servo amplifier MR-J3(W)- B, use parameter Nos. 0100 to 01FF as servo parameters. 
For control parameters, refer to the parameter list of when the servo amplifier MR-J4(W )- B is used. 
 
Classification Parameter 
No. 
(Note) Remarks 
System parameters 
No. 0001 to 007F 
 
Servo parameters 
No. 0100 to 01FF 
Each axis 
Control parameters 
No. 0200 to 02FF 
Each axis 
Note. Parameter numbers are given in hexadecimal. 
 
App. 5.16.1 System parameters 
For system parameters, only the additions and changes are listed. 
 
POINT 
 
The settings for the parameters with a * mark at the front of the abbreviation 
are validated when the system is restarted. 
 
 
Parameter 
No. 
Symbol Name 
Initial 
Value
Units
Setting 
range 
Function 
0001 
*SYSOP1  System option 1 
0000h
 
0000h 
to 0102h
0
0
SSCNET communication method
Set the SSCNET communication
method.
0: SSCNET    /H (Not use)
1: SSCNET
Make sure to set "1: SSCNET    ".
(Note) SSCNET communication
method is shared in lines
1 and 2.
Control cycle setting
Set the control cycle
[When SSCNET communication
method is 1: SSCNET    ]
0: 0.88ms
1: 0.44ms