ALARMS
The ExSite IPSXM system has seven alarm inputs, which can be programmed as high, medium or 
low priority. When an alarm is received, an input signal to the unit triggers the user-defined action 
(go to preset, run pattern, etc.) programmed for the alarm.
There are three global alarm settings:
Use the following steps to program alarm settings.
1.
Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2.
Select the alarm number:
a.
Use the joystick to position the cursor beside ALARM NUMBER.
b.
Press Iris Open. The cursor moves to the right.
c.
Move the joystick up or down to view selections. Press Iris Open to enter selection.
EXIT
LANGUAGE  
ENGLISH
UNIT INVERSION  
OFF
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
<POSITION CALIBRATION>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
PELCO EXSITE IPSXM
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
UNIT SETTINGS
RESUME  
OFF
SEQUENCE (SECS)  
5
RESET DELAY (SECS)
<ALARM SETTINGS>
BACK
EXIT
ALARMS
RESUME
This mode lets the system resume its previous activity (scan, pattern, or 
previous position) after all alarms are cleared.
SEQUENCE
This is the time the system will perform an alarm activity when more than one 
alarm of the same priority occurs at the same time.
RESET DELAY
This is the amount of time the system considers the alarm to be active after it 
has physically cleared.