Справочник Пользователя для TEAC HD-P2

Скачать
Страница из 28
 
TASCAM  HD-P Owner's Manual
Timecode
runs at a slowed down rate, the frames are always 
“non-drop” frame encoded.
• 
.00
 – This frame rate is used in both film and 
HDTV systems.
• 
.
 – This frame rate is used in both film and 
HDTV systems.
• 
.00
 – Used for PAL video.
• 
.DF
 – Standard frame rate for NTSC video with 
wall time matching the drop-frame video time.
• 
.ND
 – NTSC video with non-drop encoded 
frames.
• 
0.00DF
 – True 30 frame-per-second rate but with 
drop-frame encoded LTC.
• 
0.00ND
 – 30 frames-per-second, non-drop encoded 
LTC.
Rate Pull Up/Down
Normally a synchronized audio clock is set to be 
precisely 44,100 Hz, 48,000 Hz, and so on. There are 
some cases where it is required to run the audio at 
pull-up or pull-down rates.
The 
Rate Pull Up/Down options are:
•  23.976 – Pull Down
•  24.00 – Pull Up
•  24.975 – Pull Down
•  25.00 – Pull Up
•  29.97 – Pull Down
•  30.00 – Pull Up
FreeWheel
The HD-P2 FreeWheel setting lets you adjust how 
many bad, missing, or discontiguous timecode frames 
should elapse before dropping out of a timecode 
operation (record or play). The options are from 
1
 to 
0
 frames, or 
Infinite
. After a timecode operation has 
started when FreeWheel is set to 
Infinite
 the LTC can 
be stopped or removed and it will still continue (In 
this case, you have to press the 
STOP
 key or run out of 
memory space or power to stop the timecode opera-
tion).
Jam Sync
When timecode is set to 
Infinite
 freewheel, and a valid 
timecode source is connected, the internal timecode 
generator is started. While there is a signal, the HD-P2 
will continue to follow the external timecode. Should 
the timecode stop, the internal timecode generator 
takes over as the timecode reference until one of the 
following occurs:
   •  clock source is changed
   •  freewheel setting taken off of 
Infinite
   •  power cycle
This assumes that the internal clock, or something else, 
does not stop when the LTC is unplugged. You can 
turn on/off the timecode (via keys) or disable/enable 
timecode, and the generator will continue to run.
Trigger Mode
When FreeWheel is not set to 
Infinite
, a timecode opera-
tion will stop if LTC is lost. If LTC restarts, perhaps in 
a different position, the HD-P2 will either start another 
timecode operation (Trigger Mode of 
Auto
) or will wait 
to start another operation until the 
REC
 or 
PLAY
 keys are 
pressed (Trigger Mode of 
Single
).
Trigger on Frame
Once a timecode operation has been initiated (by 
pressing 
PLAY
 or 
REC
 with timecode on), the operation 
will start either once any incoming timecode frame is 
recognized (Trigger on Frame 
Off
) or once a particular 
timecode frame is recognized (Trigger on Frame 
On
).
Trigger-Frame
If 
Trigger Mode is set to 
Single
, then you cam specify 
the particular trigger frame in HH:MM:SS.FF format 
(Make sure you select 
Save
 and press the 
SELECT
 key 
once you have entered the frame number).
Timecode Origin
When a project is created with timecode enabled, it 
has an initial timecode origin of 01:00:00.00. This 
defines the beginning of a 24-hour “timecode day” for 
the project. If an operation hits the end of the timecode 
day (e.g. 00:59:59.29, in this case), it is stopped.
Before recording audio into the project, the user can 
modify the start/stop points of the timecode day to 
correspond with the range of external timecode that 
is expected to be used with the project. For example, 
if the user is using 30 fps code, and sets the timecode 
origin to 02:00:00.00, the timecode day will range 
from [02:00:00.00 to 23:59:59.29] and then from 
[00:00:00.00 to  01:59:59.29]. In this case, a recording 
at 00:01:30.00 will be towards the end of the 24-hour 
timecode day instead of near the beginning. This 
makes “recording over midnight” possible in time of 
day applications.
Timecode Offset
The HD-P2 can offset incoming timecode up to +/-12 
hours during playback. This is useful when the user 
wants to line up playback with a timecode source that 
uses a different timecode range than that used to origi-
nally record the material into the project. An 
On/Off 
selection allows the user to activate and deactivate 
the offset without having to reenter the numeric offset 
each time. The word 
offset
 appears on the main display 
when it is 
On
 letting the user know at a glance that a 
timecode offset is currently in effect.