Справочник Пользователя для Intel DH57JG LGA-1156 mini-ITX DDR3 1333/1066 MHz 8GB BOXDH57JG
Модели
BOXDH57JG
Intel Desktop Board DH57JG Technical Product Specification
68
4.3
Front-panel Power LED Blink Codes
Whenever a recoverable error occurs during POST, the BIOS causes the board’s front
panel power LED to blink an error message describing the problem (see Table 39).
panel power LED to blink an error message describing the problem (see Table 39).
Table 39. Front-panel Power LED Blink Codes
Type
Pattern
Note
F2 Setup/F10 Boot Menu
Prompt
Prompt
None
BIOS update in progress Off when the update begins, then on for
0.5 seconds, then off for 0.5 seconds. The
pattern repeats until the BIOS update is
complete.
pattern repeats until the BIOS update is
complete.
Video error (no add-in
graphics card installed)
graphics card installed)
On-off (0.5 second each) two times, then
3.0-second pause (off), entire pattern repeats
(blink and pause) until the system is powered
off.
3.0-second pause (off), entire pattern repeats
(blink and pause) until the system is powered
off.
For processors requiring an
add-in graphics card
add-in graphics card
Memory error
On-off (0.5 second each) three times, then
3.0-second pause (off), entire pattern repeats
(blinks and pause) until the system is powered
off.
3.0-second pause (off), entire pattern repeats
(blinks and pause) until the system is powered
off.
Thermal trip warning
Each beep will be accompanied by the following
blink pattern: .25 seconds On, .25 seconds Off,
.25 seconds On, .25 seconds Off. This will result
in a total of 32 blinks.
blink pattern: .25 seconds On, .25 seconds Off,
.25 seconds On, .25 seconds Off. This will result
in a total of 32 blinks.
4.4
BIOS Error Messages
Table 40 lists the error messages and provides a brief description of each.
Table 40. BIOS Error Messages
Error Message
Explanation
CMOS Battery Low
The battery may be losing power. Replace the battery soon.
CMOS Checksum Bad
The CMOS checksum is incorrect. CMOS memory may have been
corrupted. Run Setup to reset values.
corrupted. Run Setup to reset values.
Memory Size Decreased
Memory size has decreased since the last boot. If no memory
was removed, then memory may be bad.
was removed, then memory may be bad.
No Boot Device Available
System did not find a device to boot.