Note: The detection distance is preset and is ideal for 
most installations. Should an adjustment be required 
follow the steps below.
1.  Remove FRONT PANEL (1).  See Step 9 for  
removing front panel instructions.
2. Remove the four COVER SCREWS (2) and COVER 
(3) from ELECTRICAL BOX (4)Fig. 18. 
3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT 
BOARD. (6).
4. Keeping hands away from the front of the sensor, 
reconnect the GREY SENSOR WIRE (5) and quickly 
hang the FRONT PANEL (1) onto the ELECTRICAL 
BOX (4). Do not secure the FRONT PANEL (1) at this 
time. Note: You have 5 seconds after connecting cable 
to begin program process.
5. While the SENSOR CONTROL LED (6) is blinking 
slowly, place your hand 1 to 2 in. (30-50mm.) in front of 
the sensor. Fig. 19.
6. When the LED (6) stops blinking and stays "ON", 
move your hand to the desired position from sensor 
(detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and 
hold in place until the LED (6) begins to blink again. Fig. 
19a.
Note: Maximum Detection Zone is 15-3/4" to 31-1/2", 
(400 to 800mm ) from sensor.
               
7. Once the SENSOR CONTROL LED (6) begins to 
blink again, remove your hand from the detection zone. 
When the flashing stops, the detection distance is set.
8.  Replace COVER (3). Tighten COVER SCREWS (2) 
firmly.
9. Replace the FRONT PANEL (1). See Step 9 for 
instructions on installing front panel.
10. Actuate the FLUSH VALVE:
     A) Cover sensor with hand for 10 seconds. NOTE:
            Stand outside of sensor detection aera.
     B) Remove hand from in front of the sensor, unit will
          flush in approximately 3 seconds.
     HOW TO SET DETECTION RANGE
(If Required) ; Fig. 18 & 19
Fig. 19
Fig. 19a
15
1" - 2" (30mm - 50mm)
BLINKING LED
6
MAXIMUM
DETECTION ZONE
400mm TO  800mm
(15-3/4" TO  31-1/2")
BLINKING LED
Fig. 18
1
2
5
3
4
5
M968550 REV. 1.5