Fabric Watch
175
Alarm Notification Field Descriptions
The Alarm Notification fields are described in 
.
Table 41:  Alarm Notification Field Descriptions 
Field
Description
Selected Area
Displays the configurable areas in the drop-down menu. The 
items listed will change depending on the item selected in the 
Navigation tree. 
Name
Displays the name of the alarm.
The name of the alarm is a combination of the fabric element 
whose behavior set off the alarm:
Class
Area
Index number 
State
Displays the severity of the alarm that governs what kind of 
traps Fabric Watch employs in a response to an event. The 
State of the alarm can be Informative, Normal, or Faulty.
Reason
Displays the reason that an alarm notification was sent, such 
as Started, Changed, Exceeded, Below, Above, or In 
between.
Last Value
Displays the value of a counter (behavior variable) prior to 
the alarm. 
Current Value
Displays the value of the counter (behavior variable) that set 
off the alarms. 
Time
Displays the time and date the notification was sent from the 
switch.