Справочник Пользователя для IBM 365CS/CSD (2625)

Скачать
Страница из 630
      
 
 Symptom-to-FRU Index
The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.
  Note 
Perform the FRU replacement or actions in the
sequence shown in the “FRU/Action” columns. If a
FRU did not solve the problem, put the original part
back in the computer. Do not replace a non-defective
FRU.
This index can also be used to help you decide which
FRUs to have available when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation. In the following error codes, X can be
any number.
If no codes are available, use narrative symptoms.
If the symptom is not listed, go to “Undetermined
Problems” on page 116.
  Note 
For any IBM device not supported by the diagnostic
codes in this ThinkPad computer, see the manual for
that device.
Numeric Error Codes
Symptom / Error
FRU / Action in Sequence
10X
101  Interrupt failure.
102  Timer failure.
103
Timer interrupt failure.
104  Protected mode
failure.
105
Last 8042 command
not accepted.
107
NMI test failure.
108
Timer bus test failure.
109
Low meg-chip select
test.
  1. System Board
110
(Planar parity.)
1. Go to “Memory
Checkout” on
page  97.
  2. DIMM
3. The computer is
attached to a Port
Replicator.
  4. System Board
106
IBM Mobile Systems - ThinkPad HMM Volume 3