Справочник Пользователя для American Dryer Corp. AD-464

Скачать
Страница из 52
450260-1
www.amdry.com
27
Notes
For proper cable (wire rope) routing, starting at the
piston;
A. Replace  the  cable  (wire  rope)  thimble  and  wire  rope
clamp to one side of the cable.
B. Secure the cable (wire rope) to the piston mount with
the 3/8-16 x 1" bolt, 3/8" fender washer, 3/8" lock washer,
and 3/8-16 hex nut.
C. Feed the cable (wire rope) through the cylinder clevis
assembly  and  around  the  outer  lower  right  cable
pulley, to the upper right cable pulley, to the inner lower
right cable pulley, to the inner lower left cable pulley, to
the  outer  lower  left  cable  pulley,  and  to  the  cylinder
clevis  assembly.
D. Feed the cable (wire rope) through the wire rope clamp.
E. Feed  the  cable  (wire  rope)  thimble  through  the
turnbuckle  adjustment  rod.
F. Feed the cable (wire rope) around the wire rope thimble.
G. Feed the end of the cable (wire rope) through the wire
rope clamp and tighten.
H. Adjust the turnbuckle to the proper cable (wire rope)
tension.
8. To install new cable (wire rope), reverse Step #7 through
Step #3.
9. Reestablish the air supply to the dryer.
10. Reestablish electrical service to the dryer.
Load Door Glass Window Replacement
1. Remove  all  of  the  old  silicone  from  around  the  door
glass.
2. Clean  glass  door  opening  (with  alcohol)  to  remove  all
foreign  residue.
3. Carefully  clean  new  door  glass  with  alcohol  prior  to
installation.
4. Apply a bead of silicone (ADC P/N 170730) to the outer
perimeter of the door glass opening.
5. Carefully  insert  new  door  glass  within  the  door  glass
opening.
Important
Allow a full 72 hours for the silicone to cure.
6. Carefully trim excess silicone (with a razor blade) after
the cure time.
!
!
4. Remove the two (2) 1/4" x 1/4" poly connectors from the
piston.
5. Loosen the turnbuckle so that the cable becomes slack.
6. Loosen  the  setscrew  securing  the  cylinder  clevis
assembly to the piston shaft.
7. Remove the 5/16-24 x 1/4" socket head cap screw and
5/16" lock washer from the piston base.
8. Unscrew  the  piston  shaft  from  the  cylinder  clevis
assembly.
9. To install new door piston, reverse Step #8 through Step
#3.
10. Reestablish the air supply to the dryer.
11. Reestablish electrical service to the dryer.
Cable (Wire Rope) Replacement
1. Discontinue electrical service to the dryer.
2. Discontinue the air supply to the dryer.
3. Block the bottom load door in the closed position prior
to disassembly of any parts.
Important
Failure to block the bottom load door securely in the
closed position may result in personal injury.
4. Loosen the turnbuckle so that the cable becomes slack.
5. Remove the two (2) cable (wire rope) clamps from the
wire rope.
6. Loosen the four (4) cable (wire rope) clamp plates from
the wire rope.
7. Remove the cable (wire rope).
!