Справочник Пользователя для American Dryer Corp. AD-464

Скачать
Страница из 52
450260-1
www.amdry.com
33
!
Programmable Logic Controller (PLC) Replacement
1. Discontinue electrical power to the dryer.
2. Mark and identify the wires that will be removed for proper
reinstallation.
3. To  remove  the  PLC  from  the  mounting  rail,  using  a
screwdriver, very carefully pull out the mounting clip on
the bottom of the PLC and lift the unit out of the rail.
4. To replace the PLC, push in the top of the PLC into the
rail and then snap in the bottom of the unit.
5. Replace the wires removed in Step #2.
6. Reestablish electrical power to the dryer.
Note
Allen  Bradley  Micrologic  1200  terminals  can  be
removed  by  screws  at  each  end  without  removing
any wires from the terminal strip.
Phase  7  Microprocessor  Controller  (Computer)
Display Board Replacement
1. Discontinue electrical power to the dryer.
2. Carefully unplug JPD3 connector, the JPD4 connector,
and the keyboard (touch pad) ribbon cable.
3. Disconnect the common connector power cable (JPD6).
4. Loosen  and  remove  the  two  (2)  screws  securing  the
Phase  7  microprocessor  controller  (computer)  display
board and then remove the computer from the door.
5. To  install  new  Phase  7  microprocessor  controller
(computer) display board, reverse Step #4 through Step
#1.
Phase  7  Microprocessor  Controller  (Computer)
Input/Output (I/O) Board Replacement
1. Discontinue electrical power to the dryer.
2. Carefully  unplug  the  connectors  from  JPM9,  JPM7,
JPM11, JPM8, JPM10, JPM1, JPM2, JPM3, and JPM4.
Stamped  on  the  microprocessor  controller  (computer)
I/O board.
3. Remove the five (5) Phillips head screws securing the
I/O board to the control panel.
4. Carefully remove the I/O board from the two (2) standoffs.
Note
For replacement of the new I/O board it is important to
handle  with  care  to  avoid  any  electrical  shocks.
Damage may occur.  Proper static precautions should
be  taken.
5. To  install  new  microprocessor  controller  (computer)
input/output  (I/O)  board,  reverse  Step  #4  through
Step #1.
6. Reestablish electrical power to the dryer.
Keyboard (touch pad) Replacement
1. Discontinue electrical power to the dryer.
2. Disconnect keyboard (touch pad) ribbon cable from the
Phase  7  microprocessor  controller  (computer)  display
board.
3. Peel existing keyboard (touch pad) from the door.
4. Remove as much of the remaining adhesive (from the
removed keyboard [touch pad]) as possible.
5. Install and adhere new keyboard (touch pad).
6. Reestablish electrical power to the dryer.
Output Relays
Output  relay  #0  (drive  forward)  and  output  relay  #1  (drive
reverse) are used to perform jog functions.
Output relay #2 controls the open front door function.  When
this signal is energized, the pneumatic valve opens allowing
air into the two (2) door cable cylinders, which in turn opens
the front doors.
Output relay #3 controls the front “UP” solenoid.
Output relay #4 controls the front “DOWN” solenoid.
Output relay #5 controls rear doors open.
Output relay #6 controls the rear “UP” solenoid.
Output relay #7 controls the rear “DOWN” solenoid
Output relay #8 controls dry enable.  This gives control to the
Phase  7  board  to  start  the  drying  process.    This  signal  is
present when all the doors are closed and the dryer is level.
Output relay #9 controls supply air.  This controls the air valve
supplying air to all the dryer.
Electrical  Component  Replacement
Control Voltage Transformer Replacement
1. Discontinue electrical power to the dryer.
2. Locate the correct schematic for the specific change(s)
required and verify the wiring of the transformer using
the  schematic.
3. Verify the voltage of the new transformer.
4. Loosen  and  then  remove  the  four  (4)  wires  for  a
208-240 VAC dryer or the six (6) wires for a 380 VAC
(and higher) dryer from terminal block #3 (TB3).
5. Remove  the  four  (4)  screws  securing  the  transformer,
then remove the transformer itself.
6. To  install  new  transformer  reverse  above  steps  (Step
#5 through Step #2).
7. Reestablish electrical power to the dryer.
!