Справочник Пользователя для ARRI 416

Скачать
Страница из 240
Setting the Low Battery warning level (Mode 3) 
When the 416 is not powered by an OBB-2, it is possible 
to set the threshold at which the Low Battery warning is 
triggered. It can be set anywhere between 20.0 and 29.9 
volts.
•  Change from Mode 1 to Mode 3 by pressing the 
“MODE” button twice.
•  Press the “SET“ button. The currently set Low Battery 
warning level is displayed for 3 seconds.
•  To change the level, press the “SEL“ button 3 times to 
select the 2nd voltage digit or 4 times to select the 3rd 
voltage digit. The selected digit will blink.
•  Adjust the blinking digit with the “SET“ button.
•  Once the 2nd and 3rd voltage digits are set as 
required, press the “SEL“ button once to exit the 
adjustment mode.
Camera
Operation
MODE button
SEL / SET buttons