Справочник Пользователя для Leica TPS1200

Скачать
Страница из 226
106
Check & Adjust
5.5
Adjustment of the Circular Level
On the instrument 
step-by-step
Step
Description
1.
Level up the instrument in advance with the electronic level, assuming that 
the electronic level is correctly adjusted. SHIFT F12 to access STATUS 
Level & Laser Plummet
.
2.
The bubble must be centered. If it extends beyond the circle, use the allen 
keys supplied to centre it with the adjustment screws. Turn the instrument 
slowly 200 gon (180°). Repeat the adjustment procedure if the bubble 
does not stay centered.
TPS12_030