Справочник Пользователя для Pelco EHXM31C22-2X

Скачать
Страница из 40
 
C1301M (6/05)
33
 
Quick Programming Guide
 
(See Page 9)
 
AUX
 
An auxiliary output is a programmable signal from the system that can trigger another device to 
operate. An auxiliary output is programmable to trigger from an alarm or from a controller.
An AUX 1 command from the controller will activate the relay in the system and operate the device 
that is connected to the relay. The output of AUX 1 and AUX 2 can be connected to the alarm input 
of a system switch to activate automatic monitor switching and recording.
The following are the available AUX MODE settings:
TOGGLE (default)
Changes the state of the auxiliary output every time an AUX command is 
received from the controller.
LATCHING 
Must receive an AUX ON/AUX OFF command from the controller to turn 
the auxiliary output on/off.
MOMENTARY 
An AUX ON command from the controller turns the auxiliary output on 
for the programmed DWELL TIME. The auxiliary output will 
automatically turn off when the dwell time is finished.
EXIT
LANGUAGE  
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
PELCO EXSITE EHXM
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
UNIT SETTINGS
AUX 1 MODE  
TOGGLE
  DWELL TIME (SECS)  
1
AUX 2 MODE  
TOGGLE
  DWELL TIME (SECS)  
1
BACK
EXIT
AUX