Руководство Пользователя для Pelco C2950M-E

Скачать
Страница из 74
36
C2950M-E (8/10)
CHANGING THE DIGITAL PROCESSING SETTINGS
Figure 21. Digital Processing Page 
1. Place your mouse pointer over the Imaging tab.
2. Select General from the drop-down menu.
3. Select the mode: Manual or Auto. Auto is the default.
4. Move the slider to the left or right to change the following settings:
Sharpness Adjust/Sharpness:  Controls the clarity of detail in a scene. Move the slider to the right to increase the sharpness; move the 
slider to the left to decrease the sharpness. Increasing the sharpness also increases the image noise. The auto range of adjustment is  
–100 to 100; the auto default setting is 0 (zero). The manual range of adjustment is 0 to 100; the manual default setting is 50.
Saturation Adjust/Saturation: Controls how intense or vivid the colors are in a scene. Move the slider to the right to increase the 
saturation level; move the slider to the left to decrease the saturation level. The auto range of adjustment is –100 to 100; the auto default 
setting is 0 (zero). The manual range of adjustment is 0 to 100; the manual default setting is 50.
Contrast Adjust/Contrast: Controls gradations between the darkest and lightest portions of the scene. Move the slider to the right to 
increase the contrast; move the slider to the left to decrease the contrast. The auto range of adjustment is –100 to 100; the auto default 
setting is 0 (zero). The manual range of adjustment is 0 to 100; the manual default setting is 50.